适用场景

  • AFF8080
  • FAS8040
  • FAS 8080
  • ONTAP 9
  • 服务处理器 (SP)

问题描述

SP固件升级失败会触发节点关闭、并且事件日志中会显示以下消息:
 
Mon Mar 08 15:19:06 CET [node_name: spsm_listener: sp.update.status:debug]: params: {'reason': 'sp_startup_notify_servprocd: SP startup handler has been called.\n'}
Mon Mar 08 15:34:33 CET [node_name: servprocd: sp.servprocd.upd.evts:debug]: params: {'reason': 'SP Firmware network update has been successfully scheduled from 3.9 to 3.10'}
Mon Mar 08 15:35:52 CET [node_name: servprocd: sp.servprocd.upd.error:error]: SP update error: SP firmware update failure has been detected.
Mon Mar 08 16:18:07 CET [node_name: servprocd: sp.servprocd.upd.error:error]: SP update error: SP firmware update failure has been detected.
Mon Mar 08 16:20:33 CET [node_name: spsm_listener: callhome.sp.hbt.missed:notice]: Call home for SP HBT MISSED
Mon Mar 08 16:30:02 CET [node-name: spsm_listener: sp.heartbeat.stopped:error]: Have not received a IPMI heartbeat from the Service Processor (SP) in last 20 seconds.
Mon Mar 08 16:30:57 CET [node-name: sp_config_0: sp.update.status:debug]: params: {'reason': 'sp_bootup_notify_servprocd: SP online handler has been called  '}
Mon Mar 08 16:31:07 CET [node-name: sp_cluster_user_mgmt_wq_wq: sp.userlist.update.failed:error]: Error updating SP user information, Communication error (action 7).
Mon Mar 08 16:32:57 CET [node-name: env_mgr: sp.ipmi.lost.shutdown:EMERGENCY]: SP heartbeat stopped and cannot be recovered. To prevent hardware damage and data loss, the system will shut down in 2 minutes.
Mon Mar 08 16:34:57 CET [node-name: env_mgr: monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (System reboot to recover the SP)
Mon Mar 08 16:35:12 CET [node-name: sp_config_0: spmgmt.driver.timeout:error]: The software driver for the Service Processor (SP) detected a problem: Unable to update SP network information at this time.

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.