跳转到主内容

DS212-12 机架上的 SAS PHY 状态降级

Views:
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用于

  • DS212-12 机架
  • ONTAP 9
  • 具有 SAS 连接的 NetApp 存储系统

问题描述

  • DS212-12 架子上的 SAS PHY state 已从 12.0 Gb/s 降级到 6.0 Gb/s,在插槽 0 端口 0b 和 4c 上观察到。

 sysconfig -a 输出时没有结果:

   slot 0: SAS Host Adapter 0b (Broadcom SAS3616W rev. 2, SAS, <UP>)
       Firmware rev:    12.00.00.00
       NVDATA rev:     12.03.01.03
       Base WWN:      5:XXXXXX:XXXXXXX:e6
       Temperature:     Not Available
       Phy State:      [0] Enabled, 12.0 Gb/s
                 [1] Enabled, 12.0 Gb/s
                 [2] Enabled, 12.0 Gb/s
                 [3] Enabled, 6.0 Gb/s
       Mini-SAS HD Vendor:     MOLEX
       Mini-SAS HD Part Number:   112-00453+A0
       Mini-SAS HD Type:      Optical (850nm VCSEL) 15m end_1
       Mini-SAS HD Serial Number: 93XXXXXXXXXX29-A

       Shelf 30: DS212-12  Firmware rev. IOM12B A: 0130  IOM12B B: 0130
       Shelf 31: DS212-12  Firmware rev. IOM12B A: 0130  IOM12B B: 0130
       Shelf 32: DS212-12  Firmware rev. IOM12B A: 0130  IOM12B B: 0130
       Shelf 33: DS212-12  Firmware rev. IOM12B A: 0130  IOM12B B: 0130
       Shelf 34: DS212-12  Firmware rev. IOM12B A: 0130  IOM12B B: 0130
       Shelf 35: DS212-12  Firmware rev. IOM12B A: 0130  IOM12B B: 0130
       Shelf 36: DS212-12  Firmware rev. IOM12B A: 0130  IOM12B B: 0130
       Shelf 37: DS212-12  Firmware rev. IOM12B A: 0130  IOM12B B: 0130


    slot 4: SAS Host Adapter 4c (PMC-Sierra PM8072 rev. C, SAS, <UP>)
       MFG Part Number:   Microsemi Corp. 110-03801 rev. A0
       Part number:     111-03801+A0
       Serial number:    0BXXXXXXXF4
       Date Code:      20200921
       Firmware rev:     03.08.09.00
       Base WWN:       5:XXXXXX:XXXXXXX:08
       Temperature:     44 C
       Phy State:      [0] Enabled, 12.0 Gb/s
                 [1] Enabled, 12.0 Gb/s
                 [2] Enabled, 12.0 Gb/s
                 [3] Enabled, 6.0 Gb/s
       Mini-SAS HD Vendor:     Amphenol
       Mini-SAS HD Part Number:   112-00453+A0
       Mini-SAS HD Type:      Optical (850nm VCSEL) 15m ID:00
       Mini-SAS HD Serial Number: APXXXXXXXXXX38

       Shelf 30: DS212-12  Firmware rev. IOM12B A: 0130  IOM12B B: 0130
       Shelf 31: DS212-12  Firmware rev. IOM12B A: 0130  IOM12B B: 0130
       Shelf 32: DS212-12  Firmware rev. IOM12B A: 0130  IOM12B B: 0130
       Shelf 33: DS212-12  Firmware rev. IOM12B A: 0130  IOM12B B: 0130
       Shelf 34: DS212-12  Firmware rev. IOM12B A: 0130  IOM12B B: 0130
       Shelf 35: DS212-12  Firmware rev. IOM12B A: 0130  IOM12B B: 0130
       Shelf 36: DS212-12  Firmware rev. IOM12B A: 0130  IOM12B B: 0130
       Shelf 37: DS212-12  Firmware rev. IOM12B A: 0130  IOM12B B: 0130

  • SAS-EXPANDER-PHY-STATE 输出表明 37 号机架上的 PHY 11 已降级至 6.0 Gb/s。

Expander phy state on 0b.37 (NETAPP  :DS21212IOM12    SHXXXXXXXXXXXXX95):
                Pwr      Invald Disprt Loss   Phy   CRC   Phy
              Pwr Ccl Rsv Rls DWord  Error  Sync   Reset  Error  Change SATA
PHY/BAY STATE        ON  Cnt Cnt Cnt Count  Count  Count  Prob   Cnt   Cnt   Affiliation
------- ----------------- --- --- --- --- ------ ------ ------ ------ ------ ------ ----------------
0/P0:0 12.0 Gb/s      --- --- --- --- 0    0    0    0    0    1    ----------------
1/P0:1 12.0 Gb/s      --- --- --- --- 0    0    0    0    0    1    ----------------
2/P0:2 12.0 Gb/s      --- --- --- --- 0    0    0    0    0    1    ----------------
3/P0:3 12.0 Gb/s      --- --- --- --- 0    0    0    0    0    1    ----------------
4/P1:0 Disabled
 5/P1:1 Disabled
 6/P1:2 Disabled
 7/P1:3 Disabled
 8/P2:0 12.0 Gb/s      --- --- --- --- 0    0    0    0    0    13    ----------------
9/P2:1 12.0 Gb/s      --- --- --- --- 0    0    0    0    0    13    ----------------
10/P2:2 12.0 Gb/s      --- --- --- --- 0    0    0    0    0    13    ----------------
11/P2:3 6.0 Gb/s      --- --- --- --- 1    1    0    0    0    13    ----------------

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.