由于配对节点MB、一个PHY (内部磁盘架)的SAS适配器端口显示为速率未知
适用场景
- ONTAP 9
- FAS2820
- 内部磁盘架、SAS端口
问题描述
- 事件日志中报告以下警报:
[Node-02: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process nchm: DegradedOnlinePort_Alert[0a].
- System Manager将SAS端口报告为已降级(红色)
- PHY已在SAS端口上禁用:
slot 0: SAS Host Adapter 0c (PMC-Sierra PM8072 rev. C, SAS, <UP>)
Firmware rev: 03.08.09.00
Base WWN: 5:00a098:00f475d:38
Temperature: Not Available
Phy State: [8] Enabled, 12.0 Gb/s
[9] Enabled, 12.0 Gb/s
[10] Enabled, Rate unknown
[11] Enabled, 12.0 Gb/s
- 也可以从以下输出中检查相同的内容:
:> system node run -node <node> storage show shelf
Expander phy state on 0a.0 (NETAPP :DS212IOM6E SHXYZXXXX000000):
Pwr Invald Disprt Loss Phy CRC Phy
Pwr Ccl Rsv Rls DWord Error Sync Reset Error Change SATA
PHY/BAY STATE ON Cnt Cnt Cnt Count Count Count Prob Cnt Cnt Affiliation
------- ----------------- --- --- --- --- ------ ------ ------ ------ ------ ------ ----------------
0/P0:0 6.0 Gb/s --- --- --- --- 0 0 0 0 0 11 ----------------
1/P0:1 Rate unknown
2/P0:2 6.0 Gb/s --- --- --- --- 0 0 0 0 0 11 ----------------
重新拔插受影响节点的主板可能会暂时修复问题描述、但错误再次出现