環境

  • ONTAP 9.
  • FCP
  • Ciscoスイッチ 

問題

slifc_timeout_1: fci.device.quiesce:debug]: Adapter 1d encountered a command timeout on Disk device Switch x LUN y
slifc_timeout_1: fci.device.timeout:debug]: HBA 1d encountered a device timeout on Disk device Switch x LUN y
slifc_intrd: scsi.cmd.abortedByHost:error]: Disk device x Command aborted by host adapter
slifc_intrd: scsi.cmd.retrySuccess:debug]: Disk device z request successful after retry
fct_tpd_thread_6: scsitarget.fcp.dump:debug]: FCP target SRAM dump generated for adapter 10a, FW Initiated Dump
fct_tpd_thread_6: scsitarget.hwpfct.errorReset:notice]: An error was encountered in the FC target driver on Fibre Channel target adapter 10a. The adapter will be automatically reset to clear the status
fct_tpd_thread_7: scsitarget.hwpfct.errorReset:notice]: An error was encountered in the FC target driver on Fibre Channel target adapter 10b. The adapter will be automatically reset to clear the status
fct_tpd_thread_7: fcp.io.status:debug]: STIO Adapter 10b resetting with  ITNs and commands to drain
fct_tpd_thread_7: scsitarget.fct.reset:notice]: Resetting Fibre Channel target adapter 10b.
fct_tpd_thread_6: scsitarget.hwpfct.dump.saved:notice]: A dump for adapter 10a was stored in /etc/log/abc.dmp.gz.
  • show logging logs from Cisco switch show link resets:
FC-xx %PORT-5-IF_DOWN_LINK_FAILURE: %$VSAN 1%$ Interface fc1/xx is down (Link failure loss of signal)  
FC-xx %PORT-5-IF_UP: %$VSAN 1%$ Interface fc1/20 is up in mode F   
FC-xx %PORT-5-IF_DOWN_LINK_FAILURE: %$VSAN 1%$ Interface fc1/xx is down (Link failure loss of signal)  
FC-xx %PORT-5-IF_UP: %$VSAN 1%$ Interface fc1/xx is up 
 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.