PSU 报告 DC FAIL、AC FAIL、OFF
适用于
- AFF 和 FAS 系统
- ONTAP 9
- 电源单元 (PSU)
问题
- EMS 报告以下错误消息。
[Node-A: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
[Node-A: statd: callhome.shlf.fault:error]: Call home for SHELF_FAULT
[Node-A: dsa_worker4: ses.status.psError:alert]: DS212-12 (S/N SHFNCXXXXXXXXXX) shelf 0 on channel 0b power error for Power supply 2: critical status; AC Fail. This module is on the rear of the shelf at the bottom right.
[Node-A: dsa_worker4: callhome.shlf.power.intr:error]: Call home for SHELF POWER INTERRUPTED
或
[Node-A: dsa_worker2: ses.status.psWarning:error]: DS212-12 (S/N XXXXXXXXXXXXXXX) shelf 2 on channel 0a power warning for Power supply 2: warning status; DC undervoltage. This module is on the rear of the shelf at the bottom right.
[Node-A: dsa_worker2: callhome.shlf.ps.fault:error]: Call home for SHELF POWER SUPPLY WARNING
storage show fault显示 PSU 是CRITICAL。
Power Supplies:
Element Status Status Bytes Status Descriptions
1: CRITICAL 02,00,00,F1 DC FAIL, OFF, RQSTED ON, FAIL
2: OK 01,00,00,20 RQSTED ON
或
Element Status Status Bytes Status Descriptions
1: CRITICAL 02,00,00,F3 DC FAIL, AC FAIL, OFF, RQSTED ON, FAIL
2: OK 01,00,00,20 RQSTED ON
Fans:
Element Status Status Bytes Status Descriptions
1: CRITICAL 02,00,00,F0 OFF, FAIL
2: CRITICAL 02,00,00,F0 OFF, FAIL
3: OK 01,01,2C,21
4: OK 01,01,29,21
Enclosure:
Element Status Status Bytes Status Descriptions
1: OK 01,00,02,00 FAIL
Voltage Sensors:
Element Status Status Bytes Status Descriptions
1: UNRECOVERABLE 04,00,00,00
2: UNRECOVERABLE 04,00,00,00
3: OK 01,00,01,FB
4: OK 01,00,04,C6
- 受影响的 PSU 指示灯为琥珀色 LED。
- ENVIRONMENT 报告电压传感器错误:
Voltage Sensor installed element list: 1, 2, 3, 4; with error: 1, 2Shelf voltages by element:[1] <N/A> sensor condition <N/A> [2] <N/A> sensor condition <N/A> [3] 5.00 Volts Normal voltage range[4] 12.02 Volts Normal voltage range