跳转到主内容

电源正常工作,但报告 NO_PSN_PRESENT_ 而不是序列号

Views:
32
Visibility:
Public
Votes:
0
Category:
disk-shelves
Specialty:
hw
Last Updated:

适用于

DS224C 磁盘架电源

问题描述

  • 电源工作正常,但报告的输出类似于:
::> storage shelf show -shelf-id 11 -stack-id 4 -power
  Shelf Name: 4.11
  Stack ID: 4
  Shelf ID: 11
  Shelf UID: 50:0a:09:80:03:78:c1:36
  Serial Number: SHFHUXXXX000XXX
    Module Type: IOM6
  Model: DS2246
  Shelf Vendor: NETAPP
    Disk Count: 24
  Connection Type: SAS
  Shelf State: Online
    Status: Normal
  Power Supply Units:
    Crest  Power  Reset  PSU Operational
    ID Type Part#     Serial#     Power Rating  Factor Drawn  Capable Enabled Firmware Status
    --- ---- ------------ --------------- -------------- ------ ------- ------- ------- -------- ---------------------
     1 00  PPP-PPPPP+XX NO_PSN_PRESENT_ -        -    -    false  true   0000   normal
     2 9C  114-00065+B0 PSD041150272769 -                     -    -false  true   020F   normal
  Voltage Sensors:
  Voltage Operational
    ID   (V) Status
    --- ------- ----------------------
     1    - not-installed
     2    - not-installed
     3   5.70 normal
     4  12.300 normal
  Current Sensors:
    Current Operational
    ID   (mA) Status
    --- ------- ----------------------
     1    - not-installed
     2    - not-installed
     3  10890 normal
     4  17610 normal
  Errors:
  ------
  -
 
  • 可能在 storage fault show 中看到 VPD 故障。

Vendor Unique Element 83-IOM12B: (SAS)
Element Status Status Bytes Status Descriptions
1 [IOM12B A] : NONCRITICAL 03,0C,00,20 BACKPLANE VPD FAULT, MASTER, RESERVED
2 [IOM12B B] : OK 01,00,00,A0 RESERVED, RESERVED

  • 磁盘架日志可能显示类似于以下内容的 VPD 故障:

General Service faults
13 component(s) registered with fault tracker
Local faults:
        9: PCM 1 VPD: FAILED
        10: PCM 2 VPD: FAILED
Remote faults:
        9: PCM 1 VPD: FAILED
        10: PCM 2 VPD: FAILED

  • 当与另一个正常工作的电源交换时,该问题会跟随电源。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.