在磁盘和 IOM 重新就位后,DS460C 抽屉中的磁盘"PHY 报告未知的链路速率"
适用于
- DS460C 盘架
- 磁盘故障
问题
- 在 AutoSupport STORAGE-FAULT 或
::> system node run -node node_name -command storage show fault -v" 输出中被 IOM 绕过的磁盘。示例:
Enclosure Status: critical
Channel: 0a
Shelf: 1
Shelf Type: DS460-12
Product Serial Number: SH0123456789
Module Type: IOM12
...
27 [Bay 1]: CRITICAL 02,01,00,04 BYPASSED B, BYPASSED A, FAULT REQSTD
...
- ONTAP 事件消息警报。示例:
[node_name: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "1", module "A", drawer "3", PHY "1" is reporting an unknown link rate.
[node_name: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "1", module "B", drawer "3", PHY "1" is reporting an unknown link rate.
[node_name-01: dsa_disc: callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED
- 更换磁盘后问题仍然存在:
::> system node run -node node_name -command sasadmin expander_cli <SAS_path>.<Sheklf_ID>.<IOM_module> report_faults
...
Drawer 3:
Device 27 (1)
CRITICAL status code
BYPASSED A
BYPASSED B
- 未检测到驱动器:
::> storage disk show -disk 1.1.27
There are no entries matching your query.
- 两个 IOM 重新就位后,问题仍然存在。