磁盘和IOM重新安装后、DS460C抽盒中的磁盘"PHY报告未知链路速率"
适用场景
- DS460C磁盘架
- 磁盘故障
问题描述
- AutoSupport storage-fault/"
::> system node run -node node_name -command storage show fault -v
输出中的IOM绕过的磁盘。示例:
Enclosure Status: critical
Channel: 0a
Shelf: 1
Shelf Type: DS460-12
Product Serial Number: SH0123456789
Module Type: IOM12
...
27 [Bay 1]: CRITICAL 02,01,00,04 BYPASSED B, BYPASSED A, FAULT REQSTD
...
- ONTAP事件消息警报。示例:
[node_name: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "1", module "A", drawer "3", PHY "1" is reporting an unknown link rate.
[node_name: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "1", module "B", drawer "3", PHY "1" is reporting an unknown link rate.
[node_name-01: dsa_disc: callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED
- 在使用以下命令更换磁盘后、问题描述仍会保留:
::> system node run -node node_name -command sasadmin expander_cli <SAS_path>.<Sheklf_ID>.<IOM_module> report_faults
...
Drawer 3:
Device 27 (1)
CRITICAL status code
BYPASSED A
BYPASSED B
- 并且未检测到驱动器:
::> storage disk show -disk 1.1.27
There are no entries matching your query.
- 两个IOM重新安装后、问题描述仍会保留。