SAS通道中的PHY报告无效字错误或运行差异错误
- Views:
- 53
- Visibility:
- Public
- Votes:
- 0
- Category:
- disk-shelves<a>2009-162298</a>
- Specialty:
- metrocluster
- Last Updated:
适用场景
- 延伸型MetroCluster
- ATto FiBridge 7500 N / 7600 N
问题描述
- 一个路径、磁盘架和IOM出现无效字和运行不一致错误:
[node_name: dsa_worker5: ds.sas.running.disparity:debug]: [HST0] on channels 9a shelf ID 20 IOM A bay - reports running disparity errors.
[node_name: dsa_worker4: ds.sas.invalid.word:debug]: [HST0] on channels 9a shelf ID 20 IOM A bay - reports invalid word errors.
Storage-shelf
AutoSupport区段计数器:
Shelf name: 9a.shelf20
Shelf id: 20
Channel: 9a
Module: A
...
Shelf state: ONLINE
Module state: OK
Partial Path Link Invalid Running Loss Phy CRC Phy
Disk Port Timeout Rate DWord Disparity Dword Reset Error Change
Id State Value (ms) (Gb/s) Count Count Count Problem Count Count
--------------------------------------------------------------------------------------------
[HST0] OK 7 12.0 0 2403 768 0 0 24
[HST1] OK 7 12.0 0 0 0 0 0 24
[HST2] OK 7 12.0 0 0 0 0 0 24
[HST3] OK 7 12.0 0 0 0 0 0 24
...