节点传感器输出不起作用, BMC 更新失败,分别为 10% 和 93%
适用于
- AFF-A220
- BMC 11.5
问题
- 一个节点中的环境传感器输出失败:
::> system environment sensors show -state fault警告:无法列出节点 <node1_name> 上的条目。 timeout :操作
"environment_sensors_iterator::next()" took longer than 25 seconds tocomplete [from mgwd on node "<node_name>" (VSID: -1) to mgwd at169.254.231.159]Error: show failed: Timeout: Operation "environment_sensors_iterator::next()"took longer than 25 seconds to complete [from mgwd on node"<node1_name>" (VSID: -1) to mgwd at 169.254.231.159]- BMC 自动或手动将网络完整固件升级到 11.5 的操作将在 10% 停止:
::*> system service-processor image update-progress showIn PercentNode Progress Start Time Done End Time---------------- -------- ------------------- ------- -------------------<node1_name>
no 7/10/2020 10:50:00 10 7/10/2020 10:50:40<node2_name>
no - 0 -2 entries were displayed.RMPALMPC02::*> system service-processor image update-progress show -instance节点: <node1_name>
Latest SP Firmware Update Start Timestamp: 7/10/2020 10:50:00Latest SP Firmware Update Percentage Done: 10Latest SP Firmware Update End Timestamp: 7/10/2020 10:50:40Is Update in Progress: noNode: <node2_name>Latest SP Firmware Update Start Timestamp: -Latest SP Firmware Update Percentage Done: 0Latest SP Firmware Update End Timestamp: -Is Update in Progress: no2 entries were displayed.