节点传感器输出不起作用, BMC 更新失败,分别为 10% 和 93%
适用于
- AFF-A220
- BMC 11.5
问题
- 一个节点中的环境传感器输出失败:
::> system environment sensors show -state fault
警告:无法列出节点 <node1_name> 上的条目。 timeout :操作
"environment_sensors_iterator::next()" took longer than 25 seconds to
complete [from mgwd on node "
<node_name>" (VSID: -1) to mgwd at
169.254.231.159]
Error: show failed: Timeout: Operation "environment_sensors_iterator::next()"
took longer than 25 seconds to complete [from mgwd on node
"
<node1_name>" (VSID: -1) to mgwd at 169.254.231.159]
- BMC 自动或手动将网络完整固件升级到 11.5 的操作将在 10% 停止:
::*> system service-processor image update-progress show
In Percent
Node Progress Start Time Done End Time
---------------- -------- ------------------- ------- -------------------
<node1_name>
no 7/10/2020 10:50:00 10 7/10/2020 10:50:40
<node2_name>
no - 0 -
2 entries were displayed.
RMPALMPC02::*> system service-processor image update-progress show -instance
节点: <node1_name>
Latest SP Firmware Update Start Timestamp: 7/10/2020 10:50:00
Latest SP Firmware Update Percentage Done: 10
Latest SP Firmware Update End Timestamp: 7/10/2020 10:50:40
Is Update in Progress: no
Node:
<node2_name>Latest SP Firmware Update Start Timestamp: -
Latest SP Firmware Update Percentage Done: 0
Latest SP Firmware Update End Timestamp: -
Is Update in Progress: no
2 entries were displayed.