添加磁盘架期间节点关闭
适用场景
AFF A220
问题描述
- 在添加磁盘架期间、节点会关闭并执行接管
CLTFLT:HA Group Notification from na-tes-cl1-01 (CONTROLLER TAKEOVER COMPLETE AUTOMATIC) ALERT
- SAS扩展器映射显示了我们的跨域布线
Expanders on channel 0a:
Level 1: WWN 500a0980085ac44d, ID 1, Serial Number ' SHFHU2130000010', Product 'DS22412IOM12A ', Rev '0281', Slot B
Level 2: WWN 500a09800e362e3f, ID 0, Serial Number ' SHFHU2032000035', Product 'DS22412IOM12E ', Rev '0230', Slot A
Expanders on channel 0b:
Level 1: WWN 500a09800e3610bf, ID 0, Serial Number ' SHFHU2032000035', Product 'DS22412IOM12E ', Rev '0230', Slot B
Level 2: WWN 500a0980085abc19, ID 1, Serial Number ' SHFHU2130000010', Product 'DS22412IOM12A ', Rev '0281', Slot A
- EMS日志显示缺少多个磁盘
[Node-01: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk 0b.01.22 Shelf 1 Bay 22 [NETAPP X371_S164A960ATE NA53] S/N [XXXXXXXXXXXXXX] UID [5002538B:01BBB700:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.
[Node-01: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk 0b.01.23 Shelf 1 Bay 23 [NETAPP X371_S164A960ATE NA53] S/N [XXXXXXXXXXXXXX] UID [5002538B:01BACA30:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.