节点前警示LED亮起且温度传感器显示不可用
适用场景
- FAS2720
- BMC FW 11.7或更高版本
问题描述
- 警示LED指示灯由扩展器设置。
SP-LATEST-RUNTIME
======================
FRU LEDs
status
======================
FRU LED ID 1 is off
FRU LED ID 2 is on. Set by Expander
FRU LED ID 3 is off
FRU LED ID 4 is on
ses.status.temperatureWarning
可从EMS
日志中查看。
Sun Aug 28 16:18:02 +0900 [node-01: dsa_worker1:ses.status.temperatureWarning:alert]: DS212-12 (S/N XXXXXX) shelf 0 on channel 0b temperature warning for Temperature sensor 14: not installed or failed. Current temperature: 54 C (129 F). This module is on the rear of the shelf at the top right, on shelf module B.
Sun Aug 28 16:18:02 +0900 [node-01: dsa_worker1: ses.status.temperatureWarning:alert]: DS212-12 (S/N XXXXXX) shelf 0 on channel 0b temperature warning for Temperature sensor 15: not installed or failed. Current temperature: 34 C (93 F). This module is on the rear of the shelf at the top right, on shelf module B.
传感器14,15在上显示不可用
ENVIRONMENT
。
Temperature Sensor installed element list: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15; with error: none
Shelf temperatures by element:
[1] 23 C (73 F) (ambient) Normal temperature range
[2] 31 C (87 F) Normal temperature range
[3] 31 C (87 F) Normal temperature range
..........
[14] Unavailable
[15] Unavailable