跳转到主内容

多个节点和 NSM 上的 NoPathToNSM 警报

Views:
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
HW
Last Updated:

适用于

  • ONTAP 9
  • NS224盘架
  • 交换机附加存储

问题描述

  • 当系统以完全支持的配置布线时,接收 NoPathToNSM 警报。
  • 健康警报中报告了多个节点
  • NSM A 和 NSM B 均有报告。
  • 所有电缆都位于平台的正确端口中。
  • 在与交换机的物理连接中未发现任何问题。
  • EMS 日志将使用 cshm 从节点发送垃圾邮件,并调用两个 NSM,这可能会限制健康监测过程:

Wed Oct 22 06:24:44 -0600 [locfs1-2a: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process nchm: NoPathToNSMB_Alert[5806924427062452224].
Wed Oct 22 06:24:44 -0600 [locfs1-2a: notifyd: asup.throttle.drop:notice]: Too many AutoSupport messages in too short a time, throttling AutoSupport: HA Group Notification from locfs1-2a (Health Monitor process nchm: NoPathToNSMB_Alert[5806924427062452224]) ALERT
Wed Oct 22 06:39:44 -0600 [locfs1-2a: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process nchm: NoPathToNSMA_Alert[8217768597705498624].
Wed Oct 22 06:54:44 -0600 [locfs1-2a: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process nchm: NoPathToNSMB_Alert[6325119859186769920].
Wed Oct 22 07:39:45 -0600 [locfs1-2a: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process nchm: NoPathToNSMB_Alert[5806924427062452224].

  • 警报显示如下:
cluster::> system health alert show
        Node: node-a
      Alert ID: NoPathToNSMA_Alert
      Resource: Shelf 7.11
      Severity: Major
   Indication Time: Wed Oct 08 09:09:17 2025
      Suppress: false
     Acknowledge: false
   Probable Cause: Controller node-a is connected only to module B of
           shelf 7.11 through port e4a.
   Possible Effect: You will lose access to shelf 7.11 if module B fails.
Corrective Actions: 1. Consult the guide applicable to your NVMe storage shelf to review cabling rules for your system.
           2. Connect controller node-a to module A and module
           B of shelf 7.11.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.