IO端口温度传感器不可读
适用场景
- AFF A70
- AFF A90
问题描述
- 从SP日志中可以看到某些IO端口不可读:
Sensor Name              State          Current    Critical     Warning     Warning    Critical
                                         Reading       Low         Low         High       High
 -------------------------------------------------------------------------------------------------
 IO1 Status               normal            57          --          --          --          --
 IO1 100G CX6 Temp        normal            50 C         0 C         5 C       100 C       105 C
 IO1 100G P1 Temp         normal            35 C        -5 C        -1 C        70 C        75 C
 IO1 100G P2 Temp         nonreadable       -- C        -5 C        -1 C        70 C        75 C- 未使用带有不可读温度传感器的端口:
    slot 1: Dual 40G/100G Ethernet Controller CX6-DX
         e1a MAC Address:    d0:39:ea:c0:1b:bc (auto-100g_sr4-fd-up)
             QSFP Vendor:         FINISAR CORP
             QSFP Part Number:    FTLC9558REPM-1Y
             QSFP Serial Number:  XXXXXX
         e1b MAC Address:    d0:39:ea:c0:1b:bd (auto-unknown-fd-down)
             QSFP Vendor:        
             QSFP Part Number:   
             QSFP Serial Number: