跳转到主内容

IOM会在软件崩溃后重新启动

Views:
44
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用场景

  • ONTAP 9
  • I/O模块(IOM)
  • DS212C

问题描述

  • 由于IOM重新启动、AutoSupport报告以下警报。

HA Group Notification from Node01 (SHELF COOLING UNIT FAILED) ERROR
HA Group Notification from Node01 (DISK REDUNDANCY FAILED) ERROR

  • EMS 报告在软件 崩溃后IOM重新启动:

Thu Aug 15 22:47:49 +0900 [Node-01: storlog_admin: sla.shelf.message:debug]: params: {'type': 'SEVERITY', 'log': 'Thu Jan  1 00:00:00 1970 (   0+00:00:00.498); 02000093; U?; HAL; hal; 04; Module Reboot: Startup type 5-Crash reset'}
Thu Aug 15 22:47:49 +0900 [Node-01: storlog_admin: sla.shelf.message:debug]: params: {'type': 'SEVERITY', 'log': 'Thu Jan  1 00:00:00 1970 (   0+00:00:00.705); 0200013D; U?; HAL; hal; 02; Failure info:Client "i2cTransport 0" triggered wdg. tNow:144134120, tLast:144054059, interval:80000, failed:0'}

  • 中显示的消息 SHELF-LOG-IOM.GZ:

Thu Jan  1 00:00:00 1970 (    0+00:00:00.496); 02000027; U?; HAL; hal; 04; NDU Data Invalid.
Thu Jan  1 00:00:00 1970 (    0+00:00:00.496); 02000093; U?; HAL; hal; 04; Module Reboot: Startup type 5-Crash reset
Thu Jan  1 00:00:00 1970 (    0+00:00:00.496); 02000186; U?; HAL; hal; 04; Module Reboot: Latched power registers - EBOD = EF, ACP = EF
Thu Jan  1 00:00:00 1970 (    0+00:00:00.496); 0200011E; U?; HAL; hal; 02; Canister CPLD POST passed
Thu Jan  1 00:00:00 1970 (    0+00:00:00.496); 02000120; U?; HAL; hal; 02; Canister CPLD: V24
Thu Jan  1 00:00:00 1970 (    0+00:00:00.677); 01000001; U?; CLI; cli; 02; Failed to bind CLI command: gpio_set_bit, status 4
Thu Jan  1 00:00:00 1970 (    0+00:00:00.704); 0200013C; U?; HAL; hal; 02; Reboot after software crash.
Thu Jan  1 00:00:00 1970 (    0+00:00:00.705); 0200013D; U?; HAL; hal; 02; Failure info:Cause: 10800408, PC: 5c13170c, . Thread i2cipcwork 3
Thu Jan  1 00:00:00 1970 (    0+00:00:00.705); 0200013E; U?; HAL; hal; 02; Failed firmware version: 0120, Code Image A
Thu Jan  1 00:00:00 1970 (    0+00:00:00.705); 020001E3; U?; HAL; hal; 02; Sideband CPLD: V11

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.