合作伙伴 IOM 重新启动后无法识别 IOM

Views:
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用于

  • DS212C
  • DS224C
  • DS460C
  • IOM12B

问题描述

  • IOM-A 由于软件崩溃而重新启动

Sat Oct 04 20:27:08 +0800 [node1: storlog_admin: sla.shelf.message:debug]: params: {'type': 'SEVERITY', 'log': 'Thu Jan  1 00:00:00 1970 (   0+00:00:00.192); 02000093; U?; HAL; hal; 04; Module Reboot: Startup type 3-Internal software reset'}
Sat Oct 04 20:27:08 +0800 [node1: storlog_admin: sla.shelf.mod.reboot:notice]: Reboot event reported by module A in shelf: 0b.01.99.1, log: Thu Jan  1 00:00:00 1970 (   0+00:00:00.192); 02000093; U?; HAL; hal; 04; Module Reboot: Startup type 3-Internal software reset

  • IOM 重新启动时 AutoSupport 报告 SHELF COOLING UNIT FAILED 警报

Sat Oct 04 20:27:32 +0800 [node1: dsa_worker0: callhome.shlf.fan.warn:error]: Call home for SHELF COOLING UNIT FAILED

  • IOM-A 重新启动后,IOM-B 在 sysconfig -a 中无法识别,但系统存储配置仍在多路径 HA 中

System Storage Configuration: Multi-Path HA
Shelf 1: DS460-12  Firmware rev. IOM12B A: 0141  B: ----

  • 更换 IOM-B 或更换机箱或电源循环架将无法解决此问题。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 