即使在更换 Flash Cache 后,故障 LED 也不会关闭
适用于
- FAS2720/FAS2750
- ONTAP 9
问题描述
- 即使在更换有故障的 Flash Cache 后,故障 LED 仍然亮起。
"
NVMe device failed
"更换后仍有事件。无法通过执行以下命令清除错误事件。
示例:
::> system controller service-event delete -node node-1 -event-id 1
::> system controller service-event show
Node ID Event Location Event Description
---------------- --- ---------------------------------- ----------------------
node-01 1 Device in M.2 PCIe slot 1 in Controller A NVMe device failed
- 无法通过基板管理控制器(BMC)上的"system fru led set off"命令清除故障 LED。
示例:
BMC> priv set diag
BMC*> system fru led set 15 off
========
FRU LEDs status
======================
<snip>
FRU LED ID 14 = BMC DIMM Slot 2 Attention LED
FRU LED ID 15 = BMC NVMEM 1 Attention LED
FRU LED ID 16 = BMC BOOT DISK Attention LED
<snip>
FRU LED ID 14 is off
FRU LED ID 15 is on
FRU LED ID 16 is off
- Flash Cache 状态在
sysconfig-a
中显示Ok
。
slot 1: Flash Cache NVMe
Serial Number: S2UWNX0HCXXXXX5
Part Number: 110-00466
Hardware Revision: A0
Firmware Version: NA00
Model Name: X3311A
Capacity: 1024 GB
State: ok
- BMC 重新启动无法解决此问题。