驱动器更换后错误旁路警报
适用于
- FS4483NSM16E
- 内部磁盘架
问题描述
- 内部货架中的驱动器 (托架14,[0n.14])报告为丢失并被绕过。
- 驱动器已更换,两个控制器都将新磁盘识别为健康。
- 但是,尽管未检测到其他问题,系统仍在存储故障输出中将替换驱动器报告为来自控制器 A 的"已绕过"。
相关日志输出:
来自存储故障:
Enclosure Status: non-critical Channel: 0s Shelf: 0 Shelf Type: FS4483NSM16E Module Type: NSM16E 14 [Bay 14]: NONCRITICAL 03,0E,20,08 ENCLOSURE BYPASSED A, BYPASSED A
从存储机架数据显示,没有任何问题:
Shelf name: Partner.shelf0 Shelf id: 0 Channel: Partner Module: A Shelf UID: xx:xx:xx:xx:xx:xx:xx:xx Shelf S/N: xxxxxxxxxxx Term switch: N/A Shelf state: ONLINE Module state: OK Device Port Negotiated Medium Device Port Negotiated Received Disk Port Max Link Max Link Link Max Link Max Lane Max Lane Lane Error Bad TLP Bad DLLP Uncorrectable Correctable Id State Speed Speed Speed Speed Width width width Count Count Count Errors Errors (GT/s) (GT/s) (GT/s) (GT/s) ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ 13 ] OK 16.0 8.0 16.0 8.0 2 2 2 0 0 0 0 0 [14 ] OK 16.0 8.0 16.0 8.0 2 2 2 0 0 0 0 0 Shelf name: 0s.shelf0 Shelf id: 0 Channel: 0s Module: B Shelf UID: xx:xx:xx:xx:xx:xx:xx:xx Shelf S/N: xxxxxxxxxxxx Term switch: N/A Shelf state: ONLINE Module state: OK Device Port Negotiated Medium Device Port Negotiated Received Disk Port Max Link Max Link Link Max Link Max Lane Max Lane Lane Error Bad TLP Bad DLLP Uncorrectable Correctable Id State Speed Speed Speed Speed Width width width Count Count Count Errors Errors (GT/s) (GT/s) (GT/s) (GT/s) ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ 13 ] OK 16.0 8.0 16.0 8.0 2 2 2 0 0 0 0 0 [14 ] OK 16.0 8.0 16.0 8.0 2 2 2 0 0 0 0 0
从 Sysconfig-r 日志中也显示,没有任何问题:
stnpa1-02-st101 --------- ------ ------------- ---- ---- ---- ----- -------------- -------------- Spare disks for block checksum spare 0n.14P3 0n 0 14 NV:B 0 SSD-NVM N/A 23956/6132864 23964/6134912 (fast zeroed) spare 0n.14P2 0n 0 14 NV:B 0 SSD-NVM N/A 7313519/1872260992 7313527/1872263040 (fast zeroed) stnpa1-01-st101 spare 0n.14P1 0n 0 14 NV:A 0 SSD-NVM N/A 7313519/1872260992 7313527/1872263040 (fast zeroed)
- sysconfig -a、-r、shelf all 显示磁盘存在且运行正常。
- 只有存储故障输出继续显示托架 14 处于"已绕过"状态。