跳转到主内容

由于Fabric MetroCluster 系统中存在多个挡板、FC端口脱机

Views:
5
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster<a>2009417727</a>
Last Updated:

适用场景

  • ONTAP 9
  • 光纤连接 MetroCluster

问题描述

  • FC主机适配器开始在节点上摆动并脱机:

[Node-01: slifc_intrd: fci.link.break:error]: Link break detected on Fibre Channel adapter 2b.
[Node-01: slifc_asyncd_0: fci.adapter.link.online:info]: Fibre Channel adapter 2b link online.
[Node-01: slifc_intrd: fci.link.break:error]: Link break detected on Fibre Channel adapter 2b.
[Node-01: slifc_timeout_0: fci.link.error:error]: Could not recover link on Fibre Channel adapter 2b after 30 seconds. Taking the adapter offline.
[Node-01: slifc_intrd: fci.link.break:error]: Link break detected on Fibre Channel adapter 2b.
[Node-01: lhm_main: callhome.fc.al.link:alert]: Call home for FC-AL LINK_FAILURE (2b)

  • 在sysconfig -a输出中、端口状态显示脱机:

::> system node run -node <node> sysconfig -a

slot 2: FC Host Adapter 2b (Emulex XE201 rev. 48, <OFFLINE (hard)>)
          Board name:        111-02451
          Serial Number:     FCXXXXX828
          Firmware rev:      12.0.378.1
          Host Port Id:      N/A
          FC Node Name:      2:000:00XXXX:4fXXXX
          FC Port Name:      1:000:00XXXX:4fXXXX
          SFP Vendor:        FINISAR CORP.
          SFP Part Number:   FTLF8529P4BCVAN1
          SFP Serial Number: P3AB3S2
          SFP Capabilities:  4, 8 or 16 Gbit
          Link Data Rate:    N/A

  • 在连接到节点上FC端口的交换机端口上、可能会出现大量链路故障:

porterrshow:
          frames   enc   crc  crc    too  too  bad  enc  disc  link  loss  loss  frjt  fbsy  c3timeout   pcs   uncor
       tx     rx   in    err  g_eof  shrt long eof  out   c3   fail  sync   sig              tx    rx    err    err
  0:   2.3g   3.4g  0    0      0      0    0   0    0    500    9     0     9     0    0     0     0     0      0
  1:   2.6g   2.1g  0    0      0      0    0   0    0     9     38   0     4     0    0     0     0     0      0

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.