由于Fabric MetroCluster 系统中存在多个挡板、FC端口脱机
- Views:
- 5
- Visibility:
- Public
- Votes:
- 0
- Category:
- metrocluster
- Specialty:
- metrocluster<a>2009417727</a>
- Last Updated:
适用场景
- ONTAP 9
- 光纤连接 MetroCluster
问题描述
- FC主机适配器开始在节点上摆动并脱机:
[Node-01: slifc_intrd: fci.link.break:error]: Link break detected on Fibre Channel adapter 2b.
[Node-01: slifc_asyncd_0: fci.adapter.link.online:info]: Fibre Channel adapter 2b link online.
[Node-01: slifc_intrd: fci.link.break:error]: Link break detected on Fibre Channel adapter 2b.
[Node-01: slifc_timeout_0: fci.link.error:error]: Could not recover link on Fibre Channel adapter 2b after 30 seconds. Taking the adapter offline.
[Node-01: slifc_intrd: fci.link.break:error]: Link break detected on Fibre Channel adapter 2b.
[Node-01: lhm_main: callhome.fc.al.link:alert]: Call home for FC-AL LINK_FAILURE (2b)
- 在sysconfig -a输出中、端口状态显示脱机:
::> system node run -node <node> sysconfig -a
slot 2: FC Host Adapter 2b (Emulex XE201 rev. 48, <OFFLINE (hard)>)
Board name: 111-02451
Serial Number: FCXXXXX828
Firmware rev: 12.0.378.1
Host Port Id: N/A
FC Node Name: 2:000:00XXXX:4fXXXX
FC Port Name: 1:000:00XXXX:4fXXXX
SFP Vendor: FINISAR CORP.
SFP Part Number: FTLF8529P4BCVAN1
SFP Serial Number: P3AB3S2
SFP Capabilities: 4, 8 or 16 Gbit
Link Data Rate: N/A
- 在连接到节点上FC端口的交换机端口上、可能会出现大量链路故障:
porterrshow:
frames enc crc crc too too bad enc disc link loss loss frjt fbsy c3timeout pcs uncor
tx rx in err g_eof shrt long eof out c3 fail sync sig tx rx err err
0: 2.3g 3.4g 0 0 0 0 0 0 0 500 9 0 9 0 0 0 0 0 0
1: 2.6g 2.1g 0 0 0 0 0 0 0 9 38 0 4 0 0 0 0 0 0