问题

  • 两个节点中机箱温度的每小时错误消息。示例

[node_name-01: env_mgr: monitor.temp.unreadable:error]: The controller temperature (LED1 Temp) is not readable.
[node_name-01: env_mgr: monitor.temp.unreadable:error]: The controller temperature (LED2 Temp) is not readable.
[node_name-01: env_mgr: callhome.chassis.hitemp:error]: Call home for CHASSIS OVER TEMPERATURE

[node_name-02: env_mgr: monitor.temp.unreadable:error]: The controller temperature (LED1 Temp) is not readable.
[node_name-02: env_mgr: monitor.temp.unreadable:error]: The controller temperature (LED2 Temp) is not readable.
[node_name-02: env_mgr: callhome.chassis.hitemp:error]: Call home for CHASSIS OVER TEMPERATURE

  • AutoSupport 生成于:

HA Group Notification (CHASSIS OVER TEMPERATURE) ERROR

  • LED1 或 LED2 温度传感器故障。示例:
::> system node run -node node_name-01 -command environment chassis list-sensors
Sensor Name   State       Current   Critical    Warning    Warning   Critical
                 Reading    Low      Low      High     High
----------------------------------------------------------------------------------------
...
LED1 Temp   failed       -- C    0 C      3 C     43 C    46 C

::> system node run -node node_name-01 -command environment status chassis
Sensor Name              State          Current    Critical     Warning     Warning    Critical
                                       Reading       Low         Low         High       High
-------------------------------------------------------------------------------------------------
LED1 Temp                not_available    -- C         0 C         3 C        43 C        46 C
LED2 Temp                not_available    -- C         0 C         3 C        43 C        46 C

  • "No reading" 输出 BMC 调试日志中的 LED 传感器。示例:

LED1_Temp        | 16h     | ns     | 12.1  | No Reading                           
LED2_Temp        | 17h     | ns     | 12.1  | No Reading

LED1_Temp        | na         | degrees C  | na    | na        | 0.000     | 3.000     | 43.000    | 46.000    | na
LED2_Temp        | na         | degrees C  | na    | na        | 0.000     | 3.000     | 43.000    | 46.000    | na

  • 在某些情况下,节点也可能会 Panic 并显示以下消息:

[node_name-02: env_mgr: monitor.shutdown.chassisUnderTemp:error]: Chassis temperature is too cold: Ambient temperature is critical low. System will be shutdown immediately
[node_name-02: monitor: monitor.globalStatus.critical:EMERGENCY]: Chassis temperature is too low.. 
[node_name-02: env_mgr: monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Temperature critical)
[node_name-02: mgwd: mgwd.notify.halt.result:info]: MGWD able to notify CLAM on its HA partner node that this node is undergoing a planned shutdown (reason: E). Error: -

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.