FAS8300 环境原因关闭(多个风扇故障)
适用于
- FAS8300
- ONTAP 9
问题
- 由于多个风扇故障,节点已关闭。
[monitor.chassisFanFail.xMinShutdown:EMERGENCY]: Multiple Chassis Fan failure: System will shut down in 2 minutes.
[monitor.shutdown.cancel:notice]: Automatic shutdown sequence canceled.
[sp.reboot.sensor.unreadable:notice]: Rebooting BMC because one or more sensors are unreadable.
[callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: Fan1_1
[callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: Fan1_2
[monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Multiple fans failed)SP-LATEST-IPMI将风扇状态显示为正常,但板载 CPU 传感器显示为不可用状态。
CPU0_Temp | 24h | ns | 3.1 | Disabled
CPU1_Temp | 25h | ns | 3.2 | Disabled
Fan1_1 | 70h | ok | 29.1 | 7600 RPM
Fan2_1 | 71h | ok | 29.2 | 7600 RPM
Fan3_1 | 72h | ok | 29.3 | 7600 RPM
Fan4_1 | 73h | ok | 29.4 | 7600 RPM
Fan1_2 | 74h | ok | 29.1 | 7600 RPM
Fan2_2 | 75h | ok | 29.2 | 7600 RPM
Fan3_2 | 76h | ok | 29.3 | 7700 RPM
Fan4_2 | 77h | ok | 29.4 | 7700 RPM
- 无控制台输出。
- 从 BMC 执行
system power cycle无法解决此问题。