FAS2720 节点 BMC 在出现 PCM 不兼容错误后频繁重启
适用于
- FAS2720
- ONTAP 9
- 双控制器配置
- 双节点 BMC FW 已升级至 SU383 修复版本
问题
- HA 两个节点都在 ONTAP 事件日志中报告了风扇和中板错误:
[monitor.globalStatus.critical:EMERGENCY]: Multiple fans has failed. Chassis temperature is too high.. Disk shelf fault.
[monitor.globalStatus.critical:EMERGENCY]: Multiple fans has failed. Chassis temperature is too high..
[env_mgr: monitor.temp.unreadable:error]: The controller temperature (Midplane 4 Temp) is not readable.[env_mgr: monitor.temp.unreadable:error]: The controller temperature (Midplane 3 Temp) is not readable.[env_mgr: monitor.temp.unreadable:error]: The controller temperature (Midplane 2 Temp) is not readable.[env_mgr: monitor.temp.unreadable:error]: The controller temperature (Midplane 1 Temp) is not readable.
- HA 两个节点 BMC 频繁重启,并在 BMC 事件日志中报告
Incompatible Partner PCM:
Record 558: Wed Oct 28 21:23:55.339656 2026 [BMC.critical]: Rebooting SP due to loss of ACP commsRecord 559: Sun Jan 01 00:00:23.663873 2017 [IPMI.notice]: 0106 | c0 | OEM: ffff70005100 | ManufId: 150300 | BMC Reset InternallyRecord 680: Wed Oct 28 21:41:33.889832 2026 [ASUP.notice]: First notification email | (INVALID CHASSIS CONFIGURATION (Incompatible Partner PCM)) CRITICAL | Send failed