问题描述

  • (BATTERY (full charge capacity low)) EMERGENCY ASUP 已触发。

HA Group Notification (BATTERY (full charge capacity low)) EMERGENCY

  • 由于 NVMEM 电池错误,节点已关闭。

[env_mgr: monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Battery PCT capacity critical)

  • 节点关闭期间未发生电池学习循环。 

[IPMI.emergency]: triggered OS halt: Battery PCT capacity critic
[IPMI.notice]: d501 | 02 | EVT: 0301ffff | Attn_Sensor1 | Assertion Event, "State Asserted"
[ONTAP.notice]: Appliance user command halt.
[IPMI.notice]: d601 | 02 | EVT: 6f03ffff | Sensor 255 | Assertion Event, "Storage OS graceful shutdown"
[IPMI Event.critical]: System power down
[IPMI.emergency]: Shutdown by Data ONTAP
[Trap Event.critical]: hwassist abnormal_reboot (28)
[IPMI.notice]: d701 | 02 | EVT: 0300ffff | Power_Good | Assertion Event, "State Deasserted"
[ASUP.notice]: First notification email | (REBOOT (abnormal)) WARNING | Sent

  • Bat Pct Capacity 标记为临界低。

电池百分比容量临界低32% 39% 44% -- --

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.