FAS2650环境关闭(电池 PCT 容量关键)
适用场景
- FAS2650
- SP FW 5.4
问题描述
- 节点因NVMEM电池错误而关闭。
[cluster01:nvmem.battery.capLowCrit:EMERGENCY]: The NVMEM battery capacity is critically low (0 cycles). To prevent data loss, the system will shut down in 20 minutes.
[cluster01:callhome.battery.failure:EMERGENCY]: Call home for BATTERY (capacity low) CRITICAL.
[cluster01:callhome.battery.failure:EMERGENCY]: Call home for BATTERY (full charge capacity low) CRITICAL.
[cluster01:monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Battery PCT capacity critical)
event all
NVMEM电池学习周期开始后, SP show node down 命令。
Record 1847: Wed Jul 24 12:00:13 2024 [IPMI.notice]: 3501 | 02 | EVT: 0301ffff | Bat_Lrn_Active | Assertion Event, "State Asserted"
Record 1862: Wed Jul 24 13:18:38 2024 [IPMI.emergency]: env_mgr triggers storage OS halt: Battery PCT
Record 1865: Wed Jul 24 13:19:04 2024 [IPMI.notice]: 4501 | 02 | EVT: 6f406fff | Sensor 255 | Assertion Event, "Storage OS stop/shutdown"
system power cycle
来自SP的无法解决问题,并且节点电源状态显示。
SP cluster01> system power cycle
This command will trigger a destage of ONTAP and will take some time to complete after which the system will restart.
Use "system reset" or "system reset current" to avoid the delay. Continue? [y/n] y
SP cluster01>
SP cluster01> system power status
Host Power is off