跳转到主内容

FAS2xxx 环境停机(电池 PCT 容量临界)

Views:
163
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
HW
Last Updated:

适用于

  • FAS2620
  • FAS2650
  • FAS2750
  • FAS2720
  • NVMEM 电池

问题

  • NVMEM 电池错误导致节点关闭。
[cluster01:nvmem.battery.capLowCrit:EMERGENCY]: The NVMEM battery capacity is critically low (0 cycles). To prevent data loss, the system will shut down in 20 minutes.
[cluster01:callhome.battery.failure:EMERGENCY]: Call home for BATTERY (capacity low) CRITICAL.
[cluster01:callhome.battery.failure:EMERGENCY]: Call home for BATTERY (full charge capacity low) CRITICAL.
[cluster01:monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Battery PCT capacity critical)
  • event all NVMEM 电池学习周期开始后,SP 命令显示节点已关闭。

Record 1847: Wed Jul 24 12:00:13 2024 [IPMI.notice]: 3501 | 02 | EVT: 0301ffff | Bat_Lrn_Active | Assertion Event, "State Asserted"
Record 1862: Wed Jul 24 13:18:38 2024 [IPMI.emergency]: env_mgr triggers storage OS halt: Battery PCT
Record 1865: Wed Jul 24 13:19:04 2024 [IPMI.notice]: 4501 | 02 | EVT: 6f406fff | Sensor 255 | Assertion Event, "Storage OS stop/shutdown"

  • system power cycle 从 SP 无法解决问题,并且节点电源状态显示为关闭。

SP cluster01> system power cycle
This command will trigger a destage of ONTAP and will take some time to complete after which the system will restart.
Use "system reset" or "system reset current" to avoid the delay. Continue? [y/n] y

SP cluster01>
SP cluster01> system power status
Host Power is off

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.