在FAS25xx上、风扇转速较高且HA组通知(shelf_fault)错误频繁
适用场景
- FAS25xx
- Alternate Control Path(备用控制路径)(ACP)
- ONTAP 9
问题描述
- 系统风扇间转速很高
- AutoSupport 警报:
HA Group Notification (SHELF_FAULT) ERROR
EMS
[node-01: dsa_worker3: ses.status.ACPError:alert]: DS2126 (S/N SHJHU1642000123) shelf 0 on channel 0a ACP Processor error for SAS shelf ACP processor 2: critical status ; Alternate Control Path hardware failed This module is on the rear of the shelf at the top right, on shelf module B.
[node-01: monitor: monitor.globalStatus.critical:EMERGENCY]: Disk shelf fault.
[node-01: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
[node-01: statd: callhome.shlf.fault:error]: Call home for SHELF_FAULT
STORAGE-FAULT
Enclosure:
Element Status Status Bytes Status Descriptions
1: OK 01,00,02,00 FAIL
Vendor Unique Element 85-IOM6E: (ACP)
Element Status Status Bytes Status Descriptions
1 [IOM6E A] : OK 01,10,00,00 INBACP
2 [IOM6E B] : CRITICAL 02,10,00,40 INBACP, FAIL
Vendor Unique Element 88-IOM6E: (PCM)
Element Status Status Bytes Status Descriptions
1: OK 01,01,00,00
2: OK 01,01,00,80 PC SHELF FAULT RQSTD
SYSCONFIG-A
node-01
System ACP Connectivity: Inband Active
node-02
System ACP Connectivity: Full Connectivity
STORAGE-ACP.XML
node-01
Channel in-band
node-02
Channel out-of-band
- 重新启动SP (服务处理器)后、问题描述 仍会保留
- 禁用并重新启用ACP (备用控制路径)后、问题描述 仍会保留