环境原因停机(电池组无效)
适用场景
FAS8300
问题描述
- 紧急停机并说明原因
Battery pack invalid
。
Jun 21 07:10:06 [krsl06nfc2-02:nvmem.battery.unread:EMERGENCY]: The NVMEM battery state cannot be determined because the 'Bat Pack Invalid' sensor is unreadable. To prevent data loss, the system will shut down in 5 minutes.
Jun 21 07:11:06 [krsl06nfc2-02:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Pack Invalid' unreadable) CRITICAL.
Jun 21 07:17:06 [krsl06nfc2-02:monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Battery pack invalid)
Waiting for PIDS: 1084.
Terminated
.
Uptime: 102d17h42m31s
FM halt: Time 8876489612 ms, 22709097543240426 cycles
System powering down.
- 电池组状态:
Bat_Dsg_FET_Flt | 0x0 | discrete | 0x0480| na | na | na | na | na | na
Bat_Chg_FET_Flt | 0x0 | discrete | 0x0480| na | na | na | na | na | na
Bat_Pack_Invalid | na | discrete | na | na | na | na | na | na | na
Bat_Lrn_Active | 0x0 | discrete | 0x0180| na | na | na | na | na | na
- 问题描述在控制器通电后仍然存在