跳转到主内容

环境原因停机(电池组无效)

Views:
7
Visibility:
Public
Votes:
0
Category:
fas-systems<a>2009629585</a>
Specialty:
HW
Last Updated:

适用场景

FAS8300

问题描述

  • 紧急停机并说明原因 Battery pack invalid
Jun 21 07:10:06 [krsl06nfc2-02:nvmem.battery.unread:EMERGENCY]: The NVMEM battery state cannot be determined because the 'Bat Pack Invalid' sensor is unreadable. To prevent data loss, the system will shut down in 5 minutes.


Jun 21 07:11:06 [krsl06nfc2-02:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Pack Invalid' unreadable) CRITICAL.

Jun 21 07:17:06 [krsl06nfc2-02:monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Battery pack invalid)

Waiting for PIDS:  1084.

Terminated

.

Uptime: 102d17h42m31s

FM halt: Time 8876489612 ms, 22709097543240426 cycles

 

System powering down.
  • 电池组状态:
Bat_Dsg_FET_Flt  | 0x0        | discrete   | 0x0480| na        | na        | na        | na        | na        | na
Bat_Chg_FET_Flt  | 0x0        | discrete   | 0x0480| na        | na        | na        | na        | na        | na
Bat_Pack_Invalid | na         | discrete   | na    | na        | na        | na        | na        | na        | na
Bat_Lrn_Active   | 0x0        | discrete   | 0x0180| na        | na        | na        | na        | na        | na
  • 问题描述在控制器通电后仍然存在

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.