跳转到主内容

节点无法启动、并显示错误"Entering fm state:5 Because mbFound:0 local in headSwap:0"

Views:
15
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
HW
Last Updated:

适用场景

  • FAS2720/FAS2750
  • FAS2650
  • AFF-C250
  • FAS8300
  • 物理活动(如存储重新定位或控制器重新定位)

问题描述

  • 节点无法启动、并且BMC反复显示控制台消息。 

SP-login: mbx_inst_header_marshal:Error writing to all mailbox disk. mbx_sequencNo= 30338304

Feb 04 04:05:02 [Node-01:raid.autoPart.disabled:ALERT]: Disk auto-partitioning is disabled on this system: the system needs a minimum of 8 usable internal hard disks.

Feb 04 04:05:02 [Node--01:callhome.raid.adp.disabled:notice]: Disk auto-partitioning is disabled on this system: ADP DISABLED.

FWU 2nd trigger point
FWU has no post firmware update action registered.
Waiting for giveback...(Press Ctrl-C to abort wait)Entering FM state:5 because mbFound:0 local in headswap:0
Entering FM state:5 because mbFound:0 local in headswap:0
Entering FM state:5 because mbFound:0 local in headswap:0
Entering FM state:5 because mbFound:0 local in headswap:0
Entering FM state:5 because mbFound:0 local in headswap:0

Waiting for giveback...(Press Ctrl-C to abort wait)Entering FM state:5 because mbFound:0 local in headswap:0
Entering FM state:5 because mbFound:0 local in headswap:0

This node was previously declared dead.
Pausing to check HA partner status ...
lock was released, continuing boot ...
WARNING: 0 disks found!

Storage Adapters found:
0 Fibre Channel Storage Adapters found!
2 SAS Adapters found!
0 Parallel SCSI Storage Adapters found!
0 ATA Adapters found!

Select option 4 from the boot menu to choose disks for the root volume and spare core space.
Target Adapters found:
4 Fibre Channel Target Adapters found!
0 iSCSI Target Adapters found!

WARNING: there do not appear to be any disks attached to the system.
No root volume found.
Rebooting... (press ctrl-c during boot to break reboot loop)
Uptime: 34m32s
System rebooting...

  • 在EMS中:CLTFLT:HA Group Notification from Node-02 (CONTROLLER TAKEOVER COMPLETE AUTOMATIC - Communiction Error) ALERT
  • 当节点01关闭时、配对节点-02会记录以下事件。

Tue Feb 04 04:00:55 +0000 [Node-02: cf_main: cf.fsm.takeover.mdp:alert]: Failover monitor: takeover attempted after multi-disk failure on partner

  • SASadmin 未报告所有路径和驱动器。
  • 扩展器映射仅报告已连接一个磁盘架,但实际连接了多个磁盘架。
  • 配对节点正确报告了两个 SAS 域中的所有磁盘架和驱动器。
  • 重新启动节点不会恢复对所有磁盘架和驱动器的SAS访问。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.