由于板载 HBA 导致的引导错误"进入 FM 状态:5,因为 mbFound:0 本地在 headswap:0"
适用于
- ONTAP 9
- AFF 系统
- ASA 系统
- FAS 系统
问题
- 节点无法启动,来自 BMC 的控制台消息重复出现。
SP-login: mbx_inst_header_marshal:Error writing to all mailbox disk. mbx_sequencNo= 30338304
Feb 04 04:05:02 [Node-01:raid.autoPart.disabled:ALERT]: Disk auto-partitioning is disabled on this system: the system needs a minimum of 8 usable internal hard disks.
Feb 04 04:05:02 [Node--01:callhome.raid.adp.disabled:notice]: Disk auto-partitioning is disabled on this system: ADP DISABLED.
FWU 2nd trigger point
FWU has no post firmware update action registered.
Waiting for giveback...(Press Ctrl-C to abort wait)Entering FM state:5 because mbFound:0 local in headswap:0
Entering FM state:5 because mbFound:0 local in headswap:0
Entering FM state:5 because mbFound:0 local in headswap:0
Entering FM state:5 because mbFound:0 local in headswap:0
Entering FM state:5 because mbFound:0 local in headswap:0
Waiting for giveback...(Press Ctrl-C to abort wait)Entering FM state:5 because mbFound:0 local in headswap:0
Entering FM state:5 because mbFound:0 local in headswap:0
This node was previously declared dead.
Pausing to check HA partner status ...
lock was released, continuing boot ...
WARNING: 0 disks found!
Storage Adapters found:
0 Fibre Channel Storage Adapters found!
2 SAS Adapters found!
0 Parallel SCSI Storage Adapters found!
0 ATA Adapters found!
Select option 4 from the boot menu to choose disks for the root volume and spare core space.
Target Adapters found:
4 Fibre Channel Target Adapters found!
0 iSCSI Target Adapters found!
WARNING: there do not appear to be any disks attached to the system.
No root volume found.
Rebooting... (press ctrl-c during boot to break reboot loop)
Uptime: 34m32s
System rebooting...
- 来自 EMS:
CLTFLT:HA Group Notification from Node-02 (CONTROLLER TAKEOVER COMPLETE AUTOMATIC - Communiction Error) ALERT - Partner Node-02 在 Node-01 发生故障时记录了以下事件。
Tue Feb 04 04:00:55 +0000 [Node-02: cf_main: cf.fsm.takeover.mdp:alert]: Failover monitor: takeover attempted after multi-disk failure on partner
- SASadmin 未报告所有路径和驱动器。
- 扩展器映射仅报告连接了一个机架,而实际连接了更多机架。
- 合作伙伴节点在两个 SAS 域中都正确报告了所有机架和驱动器。
- 节点的电源循环无法恢复对所有机架和驱动器的 SAS 访问。