问题描述

  • 不同节点和磁盘架会报告多个次要事件:
Minor 13:41:47 02/17/22 13:41:48 02/17/22 node_name-1 NetApp Enclosure services device shelf_switch-1:1.123L45: Command aborted by host adapter: HA status 0x4: cdb 0x1c (pls. check node_name-1syslog:/local/rsyslog/node_name-1) messages
Minor 13:41:47 02/17/22 13:41:47 02/17/22 node_name-3 NetApp Enclosure services device shelf_switch-1:1.123L45: Command aborted by host adapter: HA status 0x4: cdb 0x1c (pls. check node_name-1syslog:/local/rsyslog/node_name-3) messages
Minor 13:41:46 02/17/22 13:41:47 02/17/22 node_name-2 NetApp Enclosure services device shelf_switch-1:1.123L45: Command aborted by host adapter: HA status 0x4: cdb 0x1c (pls. check node_name-1syslog:/local/rsyslog/node_name-2) messages
  • 针对不同磁盘架和模块中的SAS超时显示多条EMS消息:
[node_name-1: isp2400_intrd: scsi.cmd.checkCondition.bridge.SAS.timeout:debug]: Enclosure services device shelf_switch-3:2.123L45: Check Condition: CDB 0x1c: Sense Data SCSI:aborted command - (0xb - 0x88 0x1 0xf)(9024).
[node_name-1: dsa_worker0: ses.exceptionShelfLog:debug]: Retrieving Exception SES Shelf Log information on channel shelf_switch-3:6 IOM module A disk shelf ID 1.
[node_name-1: isp2400_intrd: scsi.cmd.checkCondition.bridge.SAS.timeout:debug]: Enclosure services device shelf_switch-4:1.123L45: Check Condition: CDB 0x1c: Sense Data SCSI:aborted command - (0xb - 0x88 0x1 0xf)(9010).
[node_name-1: dsa_worker5: ses.exceptionShelfLog:debug]: Retrieving Exception SES Shelf Log information on channel shelf_switch-4:7 IOM module B disk shelf ID 2.
[node_name-1: isp2400_intrd: scsi.cmd.checkCondition.bridge.SAS.timeout:debug]: Enclosure services device shelf_switch-4:1.123L45: Check Condition: CDB 0x1c: Sense Data SCSI:aborted command - (0xb - 0x88 0x1 0xf)(9015).
[node_name-1: dsa_worker4: ses.exceptionShelfLog:debug]: Retrieving Exception SES Shelf Log information on channel shelf_switch-4:7 IOM module B disk shelf ID 2.
[node_name-1: isp2400_intrd: scsi.cmd.checkCondition.bridge.SAS.timeout:debug]: Enclosure services device shelf_switch-4:1.123L45: Check Condition: CDB 0x1c: Sense Data SCSI:aborted command - (0xb - 0x88 0x1 0xf)(9053).
[node_name-1: dsa_worker3: ses.exceptionShelfLog:debug]: Retrieving Exception SES Shelf Log information on channel shelf_switch-4:7 IOM module B disk shelf ID 2.
[node_name-1: isp2400_intrd: scsi.cmd.checkCondition.bridge.SAS.timeout:debug]: Enclosure services device shelf_switch-2:2.123L45: Check Condition: CDB 0x1c: Sense Data SCSI:aborted command - (0xb - 0x88 0x1 0xf)(9045).
[node_name-1: dsa_worker4: ses.exceptionShelfLog:debug]: Retrieving Exception SES Shelf Log information on channel shelf_switch-2:6 IOM module B disk shelf ID 3.
 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.