環境

  • FAS2720
  • ONTAP 9

問題

system controller show 出力のデグレードステータス

::> system controller show

Controller Name             System ID            Serial Number       Model      Status
-------------------------  -------------------  -----------------  ----------  ----------

Ctl A                      xxxxxxxxxxxxx        xxxxxxxxxxxxxxxx   FAS2720     degraded
Ctl B                      xxxxxxxxxxxxx        xxxxxxxxxxxxxxxx   FAS2720     degraded

 

MixOfIOMAandIOMBConnection_Alert  入力 system health alert show  

Mixed IOM A and IOM B connection between disk shelves 1.2 and 1.0.

1. Consult the guide applicable to your IOM12 disk shelf to review cabling rules and complete the SAS cabling worksheet for your system.
2. Connect IOM A of disk shelf 1.2 to IOM A of disk shelf 1.0.
3. Connect IOM B of disk shelf 1.2 to IOM B of disk shelf 1.0.

SASケーブル接続 sasadmin expander_map

Expanders on channel 0a:
Level    1: WWN 500x09x00xxxxxxd, ID  1, Serial Number ' SHXXG2113xxxxxx', Product 'DS21212IOM12A   ', Rev '0260', Slot B
Level    2: WWN 500x09x00xxxxxx9, ID  2, Serial Number ' SHXXG2113xxxxxx', Product 'DS21212IOM12A   ', Rev '0260', Slot B
Level    3: WWN 500x09x00xxxxxxf, ID  0, Serial Number ' SHXXC2114xxxxxx', Product 'DS21212IOM12E   ', Rev '0220', Slot A

Expanders on channel 0b:
Level    1: WWN 500x09x00xxxxxxe, ID  0, Serial Number ' SHXXC2114xxxxxx', Product 'DS21212IOM12E   ', Rev '0220', Slot B
Level    2: WWN 500x09x00xxxxxx8, ID  2, Serial Number ' SHXXG2113xxxxxx', Product 'DS21212IOM12A   ', Rev '0260', Slot A
Level    3: WWN 500x09x00xxxxxx5, ID  1, Serial Number ' SHXXG2113xxxxxx', Product 'DS21212IOM12A   ', Rev '0260', Slot A

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.