由于HBA卡而降级OnlinePort_Alert
适用场景
- FAS或AFF系统
问题描述
DegradedOnlinePort_Alert报告在中SYSTEM-HEALTH-ALERT.XML- 在
SYSCONFIG-A中,Phy State显示Disabled。
SYSCONFIG-A:slot 1: SAS Host Adapter 1d (PMC-Sierra PM8072 rev. C, SAS, <UP>)MFG Part Number: Microsemi Corp. 110-03801 rev. A0Part number: 111-03801+A0Serial number: XXXXXXXXXXXDate Code: 20180706Firmware rev: 03.08.09.00Base WWN: 5:0000d1:7048bcc:0cTemperature: 44 CPhy State: [4] Enabled, 12.0 Gb/s [5] Disabled [6] Enabled, 12.0 Gb/s [7] Enabled, 12.0 Gb/s- 在
STORAGE-SHELF中,显示了UNKWN LNK。
STORAGE-SHELF:Shelf name: 1d.shelf1Shelf id: 1Channel: 1dModule: AShelf UID: XX:XX:XX:XX:XX:XX:XX:XXShelf S/N: XXXXXXXXXXXXXXXTerm switch: N/AShelf state: ONLINEModule state: OKPartial Path Link Invalid Running Loss Phy CRC PhyDisk Port Timeout Rate DWord Disparity Dword Reset Error ChangeId State Value (ms) (Gb/s) Count Count Count Problem Count Count--------------------------------------------------------------------------------------------------[HST0/P0:0 ] OK 7 12.0 0 0 0 0 0 13[HST1/P0:1 ] OK 7 12.0 0 0 0 0 0 13[HST2/P0:2 ] OK 7 12.0 0 0 0 0 0 13[HST3/P0:3 ] OK 7 12.0 0 0 0 0 0 13[HST4/P1:0 ] EMPTY 7 NA 0 0 0 0 0 0[HST5/P1:1 ] EMPTY 7 NA 0 0 0 0 0 0[HST6/P1:2 ] EMPTY 7 NA 0 0 0 0 0 0[HST7/P1:3 ] EMPTY 7 NA 0 0 0 0 0 0[HST8/P2:0 ] OK 7 12.0 0 0 0 0 0 19[HST9/P2:1 ] OK 7 12.0 0 0 0 0 0 19[HST10/P2:2] UNKWN LNK 7 NA 0 0 0 0 0 18[HST11/P2:3] OK 7 12.0 0 0 0 0 0 19[HST12/P3:0] EMPTY 7 NA 0 0 0 0 0 0[HST13/P3:1] EMPTY 7 NA 0 0 0 0 0 0[HST14/P3:2] EMPTY 7 NA 0 0 0 0 0 0[HST15/P3:3] EMPTY 7 NA 0 0 0 0 0 0- 即使在更换了缆线和连接到该缆线的IOM后、问题描述仍然存在。