由于HBA卡而降级OnlinePort_Alert
适用场景
- FAS或AFF系统
问题描述
DegradedOnlinePort_Alert
报告在中SYSTEM-HEALTH-ALERT.XML
- 在
SYSCONFIG-A
中,Phy State
显示Disabled
。
SYSCONFIG-A:
slot 1: SAS Host Adapter 1d (PMC-Sierra PM8072 rev. C, SAS, <UP>)
MFG Part Number: Microsemi Corp. 110-03801 rev. A0
Part number: 111-03801+A0
Serial number: XXXXXXXXXXX
Date Code: 20180706
Firmware rev: 03.08.09.00
Base WWN: 5:0000d1:7048bcc:0c
Temperature: 44 C
Phy State: [4] Enabled, 12.0 Gb/s
[5] Disabled
[6] Enabled, 12.0 Gb/s
[7] Enabled, 12.0 Gb/s
- 在
STORAGE-SHELF
中,显示了UNKWN LNK
。
STORAGE-SHELF:
Shelf name: 1d.shelf1
Shelf id: 1
Channel: 1d
Module: A
Shelf UID: XX:XX:XX:XX:XX:XX:XX:XX
Shelf S/N: XXXXXXXXXXXXXXX
Term switch: N/A
Shelf state: ONLINE
Module state: OK
Partial Path Link Invalid Running Loss Phy CRC Phy
Disk Port Timeout Rate DWord Disparity Dword Reset Error Change
Id State Value (ms) (Gb/s) Count Count Count Problem Count Count
--------------------------------------------------------------------------------------------------
[HST0/P0:0 ] OK 7 12.0 0 0 0 0 0 13
[HST1/P0:1 ] OK 7 12.0 0 0 0 0 0 13
[HST2/P0:2 ] OK 7 12.0 0 0 0 0 0 13
[HST3/P0:3 ] OK 7 12.0 0 0 0 0 0 13
[HST4/P1:0 ] EMPTY 7 NA 0 0 0 0 0 0
[HST5/P1:1 ] EMPTY 7 NA 0 0 0 0 0 0
[HST6/P1:2 ] EMPTY 7 NA 0 0 0 0 0 0
[HST7/P1:3 ] EMPTY 7 NA 0 0 0 0 0 0
[HST8/P2:0 ] OK 7 12.0 0 0 0 0 0 19
[HST9/P2:1 ] OK 7 12.0 0 0 0 0 0 19
[HST10/P2:2] UNKWN LNK 7 NA 0 0 0 0 0 18
[HST11/P2:3] OK 7 12.0 0 0 0 0 0 19
[HST12/P3:0] EMPTY 7 NA 0 0 0 0 0 0
[HST13/P3:1] EMPTY 7 NA 0 0 0 0 0 0
[HST14/P3:2] EMPTY 7 NA 0 0 0 0 0 0
[HST15/P3:3] EMPTY 7 NA 0 0 0 0 0 0
- 即使在更换了缆线和连接到该缆线的IOM后、问题描述仍然存在。