跳转到主内容

由于电缆未正确插入,导致发生降级联机Port_Alert

Views:
50
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

适用场景

  • ONTAP 9
  • FAS/AFA

问题描述

  • 节点的故障 LED亮起。
  • EMS报告 DegradedOnlinePort_Alert
 
[?]  Mon Jan 01 04:01:49 +0000 [Node: pmcsas_timeout_0: sas.cable.degraded:error]: Cable attached to SAS port "1d" is functioning in a degraded mode.
[?]  Mon Jan 01 04:02:14 +0000 [Node: nchmd: hm.alert.raised:alert]: Alert Id = DegradedOnlinePort_Alert , Alerting Resource = 1d raised by monitor node-connect
[?]  Mon Jan 01 04:04:02 +0000 [Node: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process nchm: DegradedOnlinePort_Alert[1d].
 
  • 中已禁用物理 SYSCONFIG-A
slot 1: SAS Host Adapter 1d (PMC-Sierra PM8072 rev. C, SAS, <UP>)
MFG Part Number:   Microsemi Corp. 110-03801 rev. A0
Part number:     111-03801+A0
Serial number:    XXXXXXXXXXX
Date Code:      20180706
Firmware rev:    03.08.09.00
Base WWN:      5:0000d1:7048bcc:0c
Temperature:     38 C
Phy State:      [4] Enabled, 12.0 Gb/s
           [5] Disabled
           [6] Enabled, 12.0 Gb/s
           [7] Enabled, 12.0 Gb/s

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.
  • 这篇文章对您有帮助吗?