ONTAP升级到9.13.1.后数据端口脱机
适用场景
- 采用4x10G分支模式的X91440A NIC端口
- ONTAP 9
- Cisco交换机(数据)
问题描述
- 根据 SU533 应用的临时解决策可防止系统 [1] 在执行ONTAP升级之前遇到错误ID 1512950
- 在ONTAP升级到9.13.1P7之后、HA对中两个节点的数据端口均保持脱机状态
- 节点可根据输出正确检测脱机端口:
节点cluster-01上的端口e4e已关闭、节点cluster-02上的端口e8e已关闭
CLUSTER::*> net port show
(network port show)
Node: CLUSTER-01
Ignore
Speed(Mbps) Health Health
Port IPspace Broadcast Domain Link MTU Admin/Oper Status Status
--------- ------------ ---------------- ---- ---- ----------- -------- ------
e0M Default Default up 1500 auto/1000 healthy false
...
e4a Cluster Cluster up 9000 auto/40000 healthy false
e4e Default DATA-BD down 1500 auto/- - false
...
e8a Cluster Cluster up 9000 auto/40000 healthy false
e8e Default DATA-BD up 1500 auto/10000 healthy false
Node: CLUSTER-02
Ignore
Speed(Mbps) Health Health
Port IPspace Broadcast Domain Link MTU Admin/Oper Status Status
--------- ------------ ---------------- ---- ---- ----------- -------- ------
e0M Default Default up 1500 auto/1000 healthy false
...
e4a Cluster Cluster up 9000 auto/40000 healthy false
e4e Default DATA-BD up 1500 auto/10000 healthy false
...
e8a Cluster Cluster up 9000 auto/40000 healthy false
e8e Default DATA-BD down 1500 auto/- - false
...
30 entries were displayed.
CLUSTER-01> sysconfig 4
slot 4: 10/40 Gigabit Ethernet Controller XL710 QSFP+
e4a MAC Address: XX:XX:XX:XX:XX:XX (auto-40g_sr4-fd-up)
slot 4: 10/40 Gigabit Ethernet Controller XL710 QSFP+
e4e MAC Address: XX:XX:XX:XX:XX:XX (auto-unknown-fd-down)
...
CLUSTER-01> sysconfig 8
slot 8: 10/40 Gigabit Ethernet Controller XL710 QSFP+
e8a MAC Address: XX:XX:XX:XX:XX:XX (auto-40g_sr4-fd-up)
slot 8: 10/40 Gigabit Ethernet Controller XL710 QSFP+
e8e MAC Address: XX:XX:XX:XX:XX:XX (auto-10g_sr-fd-up)
...
CLUSTER-02> sysconfig 4
slot 4: 10/40 Gigabit Ethernet Controller XL710 QSFP+
e4a MAC Address: XX:XX:XX:XX:XX:XX (auto-40g_sr4-fd-up)
slot 4: 10/40 Gigabit Ethernet Controller XL710 QSFP+
e4e MAC Address: XX:XX:XX:XX:XX:XX (auto-10g_sr-fd-up)
...
CLUSTER-02> sysconfig 8
slot 8: 10/40 Gigabit Ethernet Controller XL710 QSFP+
e8a MAC Address: XX:XX:XX:XX:XX:XX (auto-40g_sr4-fd-up)
slot 8: 10/40 Gigabit Ethernet Controller XL710 QSFP+
e8e MAC Address: XX:XX:XX:XX:XX:XX (auto-unknown-fd-down)
...
- 已使用分支缆线连接脱机端口