节点重启后数据端口关闭
适用于
- ONTAP 9
- AFF 系统
- FAS 系统
问题
- 重新启动节点 后,数据端口已关闭:
cluster::> system node run -node Node-01 -command sysconfig -aslot 1: 1G/10G Ethernet Controller CNA EP 8324
(Multiple Dual-port, QLogic CNA 8324(8362) rev. 2)
e1a MAC Address: 02:a0:98:e9:c6:72 (auto-10g_sr-fd-up)
e1b MAC Address: 00:a0:98:e9:bd:f0 (auto-unknown-fd-down)
- 在事件日志中可以看到以下消息:
[Node-01: intr: netif.linkDown:info]: Ethernet e1b: Link down, check cable.
[Node-01: vifmgr: vifmgr.portdown:notice]: A link down event was received on node Node-01, port e1b.
[Node-01: vifmgr: vifmgr.reach.unassn:notice]: Network port e1b on node Node-01 is not assigned to any broadcast domain. No broadcast domains appear to be reachable from this port.
[Node-01: vifmgr: vifmgr.reach.skipped:notice]: Network port e1b on node Node-01 was not scanned for reachability because it was administratively or operationally down at the time of the scan.
- 重新拔插 SFP 和连接到此端口的电缆后,此端口仍处于关闭状态。