DS460C:PHY X在插入磁盘后报告未知的链路速率
适用场景
DS460C磁盘架
问题描述
- 中报告温度警报
ems-log
[Node-01: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
[Node-01: dsa_worker3: ses.status.temperatureWarning:alert]: DS460-12 (S/N XXXXXXXXXXXXXXX) shelf 12 on channel 0b temperature warning for Temperature sensor 22: not installed or failed. Current temperature: 0 C (32 F). This module is on the front of the shelf 2nd drawer from the top, module B sensor 1.
[Node-01: dsa_worker3: ses.status.temperatureWarning:alert]: DS460-12 (S/N XXXXXXXXXXXXXXX) shelf 12 on channel 0b temperature warning for Temperature sensor 27: not installed or failed. Current temperature: 0 C (32 F). This module is on the front of the shelf 4th drawer from the top, module B sensor 2.
[Node-01: dsa_worker5: ses.status.temperatureWarning:alert]: DS460-12 (S/N XXXXXXXXXXXXXXX) shelf 12 on channel 0b temperature warning for Temperature sensor 20: not installed. Current temperature: C ( F). This module is on the front of the shelf 1st drawer from the top, module B sensor 1.
[Node-01: dsa_worker5: ses.status.temperatureWarning:alert]: DS460-12 (S/N XXXXXXXXXXXXXXX) shelf 12 on channel 0b temperature warning for Temperature sensor 21: not installed. Current temperature: C ( F). This module is on the front of the shelf 1st drawer from the top, module B sensor 2.
[Node-01: dsa_worker5: ses.status.temperatureWarning:alert]: DS460-12 (S/N XXXXXXXXXXXXXXX) shelf 12 on channel 0b temperature warning for Temperature sensor 23: not installed. Current temperature: C ( F). This module is on the front of the shelf 2nd drawer from the top, module B sensor 2.
- 报告未知链路速率:
[Node-01: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "X", module "B", drawer "X", PHY "X"is reporting an unknown link rate.
[Node-01: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "X", module "B", drawer "X", PHY "X" is reporting an unknown link rate.
[Node-01: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "X", module "B", drawer "X", PHY "X" is reporting an unknown link rate.
[Node-01: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "X", module "B", drawer "X", PHY "X" is reporting an unknown link rate.
ENVIRONMENT
章节报告
DCM installed element list: 1, 2, 3, 4, 5, 6, 7, 9, 10; with error: none
DCM information by element:
[1] Serial number: XXXXXXXXXX Part number: 111-04834+A0
Type: SASDRWR Vendor: NETAPP Firmware version: 01200803
.......
[8] Serial number:<N/A> Part number: <N/A>
Type: <N/A> Vendor: <N/A> Firmware version: <N/A>
Storage-fault
各部分报告:
Enclosure Status: critical
Channel: 0b
Shelf: 12
Shelf Type: DS460-12
Product Serial Number: XXXXXXXXXXXXX
Module Type: IOM12
.....
Temperature Sensors:
Element Status Status Bytes Status Descriptions
.....
22: UNKNOWN 06,00,14,00
23: OK 01,00,2D,00
24: OK 01,00,29,00
25: OK 01,00,31,00
26: OK 01,00,31,00
27: UNKNOWN 06,00,14,00
....
Drawers Control Module:
Element Status Status Bytes Status Descriptions
1 [IOM12 A] : OK 01,00,01,01 REPORT, TYPE BIT0
2 [IOM12 A] : OK 01,00,01,01 REPORT, TYPE BIT0
3 [IOM12 A] : OK 01,00,01,00 REPORT
4 [IOM12 A] : OK 01,00,01,01 REPORT, TYPE BIT0
5 [IOM12 A] : OK 01,00,01,01 REPORT, TYPE BIT0
6 [IOM12 B] : OK 01,00,01,01 REPORT, TYPE BIT0
7 [IOM12 B] : OK 01,00,01,01 REPORT, TYPE BIT0
8 [IOM12 B] : NOT AVAILABLE 07,00,00,00
9 [IOM12 B] : OK 01,00,01,01 REPORT, TYPE BIT0
10 [IOM12 B] : OK 01,00,01,01 REPORT, TYPE BIT0
- 在重新拔插/更换IOM后、问题描述仍然存在
- 抽屉更换无帮助