AFF A400、FAS8300 或 FAS8700 上的 CriticalFruNotPresentAlert
适用于
- ONTAP 9
- AFF A400
- FAS8300
- FAS8700
问题描述
CriticalFruNotPresentAlert
针对风扇模块的报告:
Alert ID: CriticalFruNotPresentAlert:Fan4 is not present in the chassis 01212341211
Node: netapp-01
Monitor: chassis
Alert ID: CriticalFruNotPresentAlert
Alerting Resource: Fan4#123456789000
Subsystem: Environment
Indication Time: Fri SEP 18 23:20:06 2020
Perceived Severity: Critical
Probable Cause: Configuration_error
Description:
Fan4 is not present in the chassis 01212341211. The nodes in this chassis are netapp-01
Corrective Actions:
1. Plug in Fan4 correctly into the slot.
2. Refer to the Hardware specification guide for more information on the position of the field-replaceable unit (FRU)
3. Contact support personnel if the alert persists.
Possible Effect:
The nodes in the chassis might not function effectively or redundancy might be lost.
Acknowledge: false
Suppress: false
Policy: CriticalFruNotPresentAlertPolicy
Acknowledger: -
Suppressor: -
Additional Information: Serial No of the FRU: Fan4#123456789000
- 在 EMS 中报告 hm.alert.raised:alert 后,它可能会自行恢复。
[cphmd: hm.alert.raised:alert]: Alert Id = CriticalFruNotPresentAlert , Alerting Resource = Fan1#042247006866 raised by monitor chassis
[cphmd: hm.alert.raised:alert]: Alert Id = CriticalFruNotPresentAlert , Alerting Resource = Fan2#042247006866 raised by monitor chassis
[cphmd: hm.alert.raised:alert]: Alert Id = CriticalFruNotPresentAlert , Alerting Resource = Fan3#042247006866 raised by monitor chassis
[cphmd: hm.alert.raised:alert]: Alert Id = CriticalFruNotPresentAlert , Alerting Resource = Fan4#042247006866 raised by monitor chassis
~
[cphmd: hm.alert.cleared:notice]: Alert Id = CriticalFruNotPresentAlert , Alerting Resource = Fan1#042247006866 cleared by monitor chassis
[cphmd: hm.alert.cleared:notice]: Alert Id = CriticalFruNotPresentAlert , Alerting Resource = Fan2#042247006866 cleared by monitor chassis
[cphmd: hm.alert.cleared:notice]: Alert Id = CriticalFruNotPresentAlert , Alerting Resource = Fan3#042247006866 cleared by monitor chassis
[cphmd: hm.alert.cleared:notice]: Alert Id = CriticalFruNotPresentAlert , Alerting Resource = Fan4#042247006866 cleared by monitor chassis
- 除 FRU INFO 外,所有风扇传感器均显示风扇正常工作
Fan4 FRU INFO discrete failed
- BMC 传感器显示 FRU ID 不可读
FRU Device Description : Fan4_FRU (ID 8)
Unknown FRU header version 0xff