适用场景
- ONTAP 9
- FAS/AFA系统
问题描述
- 事件日志中会显示以下警报:
[Node-01: cphmd: hm.alert.raised:alert]: Alert Id = CriticalFruNotPresentAlert , Alerting Resource = PSU1 FRU#95210XXXXXX raised by monitor chassis
[Node-01: cphmd: hm.alert.raised:alert]: Alert Id = CriticalFruNotPresentAlert , Alerting Resource = PSU2 FRU#95210XXXXXX raised by monitor chassis
system health alert show
命令的输出 报告相同的警报:
Cluster1::*> system health alert show
Node: Node-01
Alert ID: CriticalFruNotPresentAlert
Resource: PSU2 FRU#95210XXXXXX
Severity: Critical
Indication Time: Sat May 13 13:46:10 2023
Suppress: false
Acknowledge: false
Probable Cause: PSU2 FRU is not present in the chassis 95210XXXXXX.
The nodes in this chassis are Node-01.
Possible Effect: The nodes in the chassis might not function
effectively or redundancy might be lost.
Corrective Actions: 1. Plug in PSU2 FRU correctly into the slot.
2. Refer to the Hardware specification guide for more information on the position of the field-replaceable unit (FRU) and ways to check or replace it.
3. Contact support personnel if the alert persists.
- 受影响节点会报告缺少的CRU无法访问:
Cluster1::*> system controller fru show
Node FRU Name Subsystem Status
------------------ ---------------------------- ------------------ -----------
Node-01 PSU1 FRU Environment unreachable
Node-01 PSU2 FRU Environment unreachable
- 同一个CRU从配对节点报告正常状态:
Node FRU Name Subsystem Status
------------------ ---------------------------- ------------------ -----------
Node-02 PSU1 FRU Environment ok
Node-02 PSU2 FRU Environment ok
- 受影响节点上的SP/BMC已是最新版本。
- 下可能不会显示缺失FRU的详细信息
system chassis fru show
::> system chassis fru show
Chassis ID FRU Type State Nodes Sharing the FRU
------------------- ---------- -------- ----------- -----------------------
95210XXXXXXXX Fan2 fan GOOD Node-02
95210XXXXXXXX Fan2 fan GOOD Node-01
95210XXXXXXXX Fan1 fan
- 对节点执行接管/返回没有任何帮助。