HA对中的单个节点上报告了CritialFruNotPresentAlert

适用场景

  • ONTAP 9
  • FAS/AFA系统

问题描述

  • 事件日志中会显示以下警报:

[Node-01: cphmd: hm.alert.raised:alert]: Alert Id = CriticalFruNotPresentAlert , Alerting Resource = PSU1 FRU#95210XXXXXX raised by monitor chassis
[Node-01: cphmd: hm.alert.raised:alert]: Alert Id = CriticalFruNotPresentAlert , Alerting Resource = PSU2 FRU#95210XXXXXX raised by monitor chassis

  • system health alert show 命令的输出 报告相同的警报:

Cluster1::*> system health alert show

        Node: Node-01
      Alert ID: CriticalFruNotPresentAlert
      Resource: PSU2 FRU#95210XXXXXX
      Severity: Critical
   Indication Time: Sat May 13 13:46:10 2023
      Suppress: false
     Acknowledge: false
   Probable Cause: PSU2 FRU is not present in the chassis 95210XXXXXX.
           The nodes in this chassis are Node-01.
   Possible Effect: The nodes in the chassis might not function
           effectively or redundancy might be lost.
Corrective Actions: 1. Plug in PSU2 FRU correctly into the slot.
           2. Refer to the Hardware specification guide for more information on the position of the field-replaceable unit (FRU) and ways to check or replace it.
           3. Contact support personnel if the alert persists.

  • 受影响节点会报告缺少的CRU无法访问:

Cluster1::*> system controller fru show
Node         FRU Name            Subsystem      Status
------------------ ---------------------------- ------------------ -----------
Node-01        PSU1 FRU            Environment     unreachable
Node-01        PSU2 FRU            Environment     unreachable

  • 同一个CRU从配对节点报告正常状态:

Node         FRU Name            Subsystem      Status
------------------ ---------------------------- ------------------ -----------
Node-02        PSU1 FRU            Environment     ok
Node-02       PSU2 FRU            Environment     ok

  • 受影响节点上的SP/BMC已是最新版本。
  •  下可能不会显示缺失FRU的详细信息 system chassis fru show

::> system chassis fru show

Chassis ID      FRU     Type    State     Nodes Sharing the FRU
------------------- ---------- -------- ----------- -----------------------
95210XXXXXXXX     Fan2     fan    GOOD       Node-02
95210XXXXXXXX     Fan2     fan    GOOD     Node-01
95210XXXXXXXX    Fan1    fan 

  • 对节点执行接管/返回没有任何帮助。       

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.