跳转到主内容

集群端口e0a和e0b关闭、导致出现崩溃

Views:
62
Visibility:
Public
Votes:
1
Category:
fas-systems
Specialty:
hw
Last Updated:

 

适用场景

  • AFF A300、FAS8200
  • AFF A200、FAS2650、FAS2620
  • AFF A220、AFF C190、FAS2750、FAS2720
  • 采用无交换机配置的双节点集群
  • 启用连接、流畅度和可用性监控器(VANM)的原因是:
    • ONTAP 9.8或更高版本
    • 或配置有SAN实体的集群

问题描述

  • 两个节点上的集群网络端口e0a和e0b几乎同时关闭:

Tue Oct 03 11:08:31 CEST [node1: ixgbe/e0b: snmp.link.down:info]: Interface 2 is down.
Tue Oct 03 11:08:31 CEST [node1: ixgbe/e0b: netif.linkDown:info]: Ethernet e0b: Link down, check cable.
Tue Oct 03 11:08:31 CEST [node1: ixgbe/e0a: snmp.link.down:info]: Interface 1 is down.
Tue Oct 03 11:08:31 CEST [node1: ixgbe/e0a: netif.linkDown:info]: Ethernet e0a: Link down, check cable.

Tue Oct 03 11:08:32 CEST [node2: ixgbe/e0b: snmp.link.down:info]: Interface 2 is down.
Tue Oct 03 11:08:32 CEST [node2: ixgbe/e0b: netif.linkDown:info]: Ethernet e0b: Link down, check cable.
Tue Oct 03 11:08:32 CEST [node2: ixgbe/e0a: snmp.link.down:info]: Interface 1 is down.
Tue Oct 03 11:08:32 CEST [node2: ixgbe/e0a: netif.linkDown:info]: Ethernet e0a: Link down, check cable.

  • 其中一个节点发生"仲裁不足"崩溃。

PANIC  : Received PANIC packet from partner, receiving message is (Coredump and takeover initiated because Connectivity, Liveliness and Availability Monitor (CLAM) has determined this node is out of quorum.

  • 接管已启动、接管集群的节点正在提供数据

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.