"机箱温度太高:HIC2 Temp1 警告为高温 (101 C)"警报
适用于
- FAS500f
- Baseboard Management Controller (BMC) 固件 15.4
问题
- 节点每小时报告一次"
CHASSIS OVER TEMPERATURE"。 - 可在事件日志中找到以下错误。
[env_mgr: monitor.chassisTemperature.warm:alert]: Chassis temperature is too warm: HIC2 Temp1 is warning high (101 C). [monitor: monitor.globalStatus.critical:EMERGENCY]: Chassis temperature is too high.. [env_mgr: callhome.chassis.hitemp:error]: Call home for CHASSIS OVER TEMPERATURE- "
SP-LATEST-IPMI" 环境平台传感器输出为:
HIC1_TEMP0 | 79.000 | degrees C | ok | 1.000 | 3.000 | 5.000 | 101.000 | 103.000 | 105.000
HIC1_TEMP1 | 81.000 | degrees C | ok | 1.000 | 3.000 | 5.000 | 101.000 | 103.000 | 105.000
HIC2_TEMP0 | 93.000 | degrees C | ok | 1.000 | 3.000 | 5.000 | 101.000 | 103.000 | 105.000
HIC2_TEMP1 | 101.000 | degrees C | nc | 1.000 | 3.000 | 5.000 | 101.000 | 103.000 | 105.000
Sysfan1_F1_Speed | 9516.000 | RPM | ok | 0.000 | 936.000 | 2964.000 | 33072.000 | 34008.000 | 34944.0
Sysfan1_F2_Speed | 10296.000 | RPM | ok | 0.000 | 936.000 | 2964.000 | 33072.000 | 34008.000 | 34944.0
Sysfan2_F1_Speed | 9204.000 | RPM | ok | 0.000 | 936.000 | 2964.000 | 33072.000 | 34008.000 | 34944.0
Sysfan2_F2_Speed | 9984.000 | RPM | ok | 0.000 | 936.000 | 2964.000 | 33072.000 | 34008.000 | 34944.0
Sysfan3_F1_Speed | 9516.000 | RPM | ok | 0.000 | 936.000 | 2964.000 | 33072.000 | 34008.000 | 34944.0
Sysfan3_F2_Speed | 10296.000 | RPM | ok | 0.000 | 936.000 | 2964.000 | 33072.000 | 34008.000 | 34944.0
Sysfan4_F1_Speed | 9204.000 | RPM | ok | 0.000 | 936.000 | 2964.000 | 33072.000 | 34008.000 | 34944.0
Sysfan4_F2_Speed | 9984.000 | RPM | ok | 0.000 | 936.000 | 2964.000 | 33072.000 | 34008.000 | 34944.0
Sysfan5_F1_Speed | 9204.000 | RPM | ok | 0.000 | 936.000 | 2964.000 | 33072.000 | 34008.000 | 34944.0