跳转到主内容

由于AF-A250中的机箱风扇FRU出现故障、请致电主页

Views:
10
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

适用场景

  • AF-A250
  • BMC固件。15.10.
  • ONTAP 9

问题描述

  • 事件日志中报告了以下错误:

[Node-02: env_mgr: monitor.chassisFan.stop:debug]: Chassis fan contains at least one stopped fan: Fan1 (0 RPM)
[Node-02: env_mgr: callhome.c.fan.fru.fault:debug]: Call home for CHASSIS FAN FRU FAILED: Fan1

[Node-04: env_mgr: monitor.chassisFan.stop:debug]: Chassis fan contains at least one stopped fan: Sysfan4_F2_Speed (failed)
[Node-04: env_mgr: callhome.c.fan.fru.fault:debug]: Call home for CHASSIS FAN FRU FAILED: Sysfan4_F2_Speed

  • 一个或两个风扇的传感器状态位于 "BAD" SP传感器部分:

Fan2 State     discrete     normal          normal     GOOD
Fan1 State     discrete    fault          normal    BAD

Sensor name    | reading   | unit  | status| lnr     | lcr     | lnc     | unc     | ucr     | unr   
Sysfan4_F1_Speed | 9204.000   | RPM  | ok   | 0.000    | 936.000   | 2964.000  | 33072.000 | 34008.000 | 34944.000 
Sysfan4_F2_Speed | 0.000    | RPM  | nr   | 0.000    | 936.000   | 2964.000  | 33072.000 | 34008.000 | 34944.000 

  • 换用已知工作正常的风扇位置后、同一插槽中仍然存在错误。

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.