问题

  • 在事件日志中报告以下错误:

[Node-02: env_mgr: monitor.chassisFan.stop:debug]: Chassis fan contains at least one stopped fan: Fan1 (0 RPM)
[Node-02: env_mgr: callhome.c.fan.fru.fault:debug]: Call home for CHASSIS FAN FRU FAILED: Fan1

或

[Node-04: env_mgr: monitor.chassisFan.stop:debug]: Chassis fan contains at least one stopped fan: Sysfan4_F2_Speed (failed)
[Node-04: env_mgr: callhome.c.fan.fru.fault:debug]: Call home for CHASSIS FAN FRU FAILED: Sysfan4_F2_Speed

  • 一个或两个风扇的传感器状态在 SP 传感器部分为 "BAD":
Fan2 State     discrete     normal          normal     GOOD
Fan1 State     discrete     fault           normal     BAD
 
Sensor name    | reading   | unit  | status| lnr     | lcr     | lnc     | unc     | ucr     | unr   
Sysfan4_F1_Speed | 9204.000   | RPM  | ok   | 0.000    | 936.000   | 2964.000  | 33072.000 | 34008.000 | 34944.000 
Sysfan4_F2_Speed | 0.000   | RPM  | nr   | 0.000    | 936.000   | 2964.000  | 33072.000 | 34008.000 | 34944.000 
 
或
   Fan1_1       | 70h | ok  | 29.1 | 9100 RPM
   Fan2_1       | 71h | ok  | 29.2 | 9000 RPM
   Fan3_1       | 72h | ok  | 29.3 | 9100 RPM
   Fan4_1       | 73h | ok  | 29.4 | 9100 RPM
   Fan1_2      | 74h | ns  | 29.1 | No Reading
   Fan2_2       | 75h | ok  | 29.2 | 9200 RPM
   Fan3_2       | 76h | ok  | 29.3 | 9000 RPM
   Fan4_2       | 77h | ok  | 29.4 | 9100 RPM
  •  SP-LATEST-RUNTIME 报告节点注意 LED 亮起:

1  LED_SYSTEM_ATTEN_01 is on
50 LED_FAN_ATTEN_02 is on

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.