问题描述
来自控制台的错误报告:
WARNING:  The battery is experiencing a critical failure:
 - Battery charge FET is off
 Without a working battery, the system cannot retain data
 during a power outage, which can result in data loss.
 Power down the system and verify that the battery is
 properly installed.
 To ignore this failure and boot the system in a mode
 where data loss might occur, press 'c' followed by 'Enter'
- 节点引导失败,报告以下错误:
 
Nov 29 06:51:03 [Node:callhome.battery.failure:EMERGENCY]: Call home for BATTERY (discharge FET off) CRITICAL.
 Nov 29 06:51:48 [Node:callhome.chassis.overtemp:EMERGENCY]: Call home for CHASSIS OVER TEMPERATURE SHUTDOWN
 Nov 29 07:38:34 [Node:nv.flash.unable.to.monitor:ALERT]: Unable to monitor NVRAM device "NVRAM12".
 Nov 29 07:50:12 [Node:nvram.battery.dischargeFET.off:EMERGENCY]: The NVRAM battery discharge FET is off. To prevent data loss, the system will shut down in 20 minutes.
 Nov 29 07:50:34 [Node:monitor.temp.unreadable:error]: The controller temperature (NVRAM M2 Temp) is not readable.
 Nov 29 07:50:34 [Node:monitor.temp.unreadable:error]: The controller temperature (NVRAM FPGA Temp) is not readable.
 Nov 29 07:50:56 [Node:monitor.chassisTemperature.state.unknown:ALERT]: Chassis temperature state is unknown: BBU/NVRAM temp sensors are unreadable. System will be shutdown in 2 minutes.
 Nov 29 07:51:12 [Node:callhome.battery.failure:EMERGENCY]: Call home for BATTERY (discharge FET off) CRITICAL.
 Nov 29 07:51:56 [Node:callhome.chassis.overtemp:EMERGENCY]: Call home for CHASSIS OVER TEMPERATURE SHUTDOWN
- BMC 固件是最新的。