问题

  • 多个端口和节点的集群网络端口中 CRC 错误增加。::> system node run -node_name -command ifstat -a 示例:
-- interface  e3a  (1 hour, 20 minutes, 0 seconds) --
RECEIVE
Total frames:    123m | Frames/second:   456  | Total bytes:    789g
Bytes/second:    111m | Total errors:    222  | Errors/minute:    0
Total discards:    0  | Discards/minute:   0  | Multi/broadcast:  999
Non-primary u/c:   0  | Errored frames:    0  | Unsupported Op:    0
CRC errors:     222  | Runt frames:     0  | Fragment:       0
...
-- interface  e3b  (1 hour, 20 minutes, 0 seconds) --
RECEIVE
Total frames:    234m | Frames/second:   567  | Total bytes:    890g
Bytes/second:    222m | Total errors:    333  | Errors/minute:    0
Total discards:    0  | Discards/minute:   0  | Multi/broadcast:  888
Non-primary u/c:   0  | Errored frames:    0  | Unsupported Op:    0
CRC errors:     333  | Runt frames:     0  | Fragment:       0
...
  • 交换机端口传输错误,只有一个端口接收错误:

注意:asup 文件 CLUSTER-SWITCH-INTERFACE.XML 可以用来查看集群交换机上的输入/输出错误。  此文件将仅位于监控交换机的节点上

switch_name# show interface Ethernet1/1
RX
62347 input error  0 short frame  0 overrun  0 underrun  0 ignored
 
switch_name# show interface Ethernet1/2
TX
44 output error  0 collision  0 deferred  0 late collision
...
switch_name# show interface Ethernet1/10
TX
6 output error  0 collision  0 deferred  0 late collision
  • 交换机端口 1/1 LED 在橙色-关闭-绿色之间持续闪烁
  • 根据 network device-discovery show 输出,所有在存储上报告错误的节点/端口都连接到同一个交换机

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.