跳转到主内容

BIOS POST失败- SP IPMI故障中止自动启动

Views:
18
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用场景

  • FAS2750
  • BMC FW 11.6.

问题描述

节点已关闭且无法启动、并且BMC)固件无法更新: BIOS POST Failure(s) detected: SP IPMI failure. Abort AUTOBOOT

  • 重新安装控制器不能解决 问题描述问题
  • BMC-SP启动、通过控制台缆线:
    • 系统尝试更新到FW 11.10失败、然后重新启动
  • 通过IP控制台访问BMC-SP:
    • 系统通过"版本"将11.5和11.2显示为备份映像
    • 备份映像显示为已加载

 

  • 从中可以看到失败消息 Loader

Boot Loader version 6.0.17
Copyright (C) 2000-2003 Broadcom Corporation.
Portions Copyright (C) 2002-2023 NetApp, Inc. All Rights Reserved.
BIOS POST Failure(s) detected: SP IPMI failure. Abort AUTOBOOT
LOADER-A>

  • 连续 Syslog messages

Dec  1 04:08:46 BMC env_mgr[2526]: isvc_send_request: 454: ISVCLIB command(4) rsp timed out
Dec  1 04:08:46 BMC env_mgr[2526]: SES page request returned error (2)
Dec  1 04:08:46 BMC env_mgr[2526]: Error opening ses, err -1
Dec  1 04:08:46 BMC env_mgr[2526]: cdev_reopen: error opening device 'ses', err -1.
Dec  1 04:08:46 BMC env_mgr[2526]: cdevices_poll_pending: cdev(2001) re-open, state is 4.
Dec  1 04:09:50 BMC env_mgr[2526]: isvc_send_request: 387: ISVCLIB received msg seq_id 1751 (expected 1807)

  • 重复 events

Record 1455: Fri Dec 01 04:09:18.730000 2023 [ASUP.notice]: First notification email | (INVALID CHASSIS CONFIGURATION (Incompatible Partner PCM)) CRITICAL | Send failed

  • 输出 storage failover hwassist show

Warning: Unable to list entries on node <nodename>. RPC: Couldn't make
     connection [from mgwd on node "<nodename>" (VSID: -1) to mgwd at
     <ip-address>] 

Partner: <nodename>
Hwassist Enabled: -
Hwassist IP: -
Hwassist Port: -
Monitor Status: filer in takeover mode
Inactive Reason: -
Corrective Action: -
Keep-Alive Status: -

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.