跳转到主内容

控制器上的琥珀色 LED

Views:
2
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

适用于

FAS/AFF 系统

问题描述

  • 琥珀色指示灯亮起,但未发现可见问题或警报:

Cluster::> System health alert show
This table is currently empty.

  • 检查日志 SP-LATEST-IPMI 我们看到有一个旧故障,在检查日志后,已解决但未清除

======================================
hsamcmd --fault-show-all
======================================
tag  origin  fld                    fault reason                   count  time
---- ------- ----                   -------------                   ------ -----
1   bmc    /chassis-1/controller-a/nvbatt-1     Bat_Design_Cap: Current Sensor 95 UNC       1    Mon Dec 30 09:33:40 2024

  • 正在检查我们可以看到已报告的事件:

Cluster::> system controller service-event show -instance         
            Node: Node-01
Service Event ID: 1
      Location: NV Battery on Controller A
    Description: Bat_Design_Cap: Current Sensor 95 UNC
     Timestamp: Mon Dec 30 09:33:40 2024

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 