跳转到主内容

AFF 环境原因关闭(多个风扇故障)

Views:
Visibility:
Public
Votes:
0
Category:
aff-series
Specialty:
hw
Last Updated:

适用于

  • AFF A20
  • AFF C30
  • ONTAP 9

问题描述

  • 由于多风扇故障错误,节点已关闭。

EMS 日志:

[node01: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: Sysfan5 F1 Speed (0 RPM)
[node01: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: Sysfan1 F1 Speed (0 RPM)
[node01: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: Sysfan2 F1 Speed (0 RPM)
[node01: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: Sysfan3 F1 Speed (0 RPM)
[node01: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: Sysfan4 F1 Speed (0 RPM)
[node01: env_mgr: monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Multiple chassis fans have failed.
[node01: env_mgr: monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Multiple fans failed)
[node01: mgwd: mgwd.notify.halt.result:info]: MGWD able to notify CLAM on its HA partner node that this node is undergoing a planned shutdown (reason: E). Error: -
[node01: monitor: monitor.globalStatus.critical:EMERGENCY]: Multiple fans has failed: Sysfan5 F1, Sysfan1 F1, Sysfan2 F1, Sysfan3 F1, Sysfan4 F1. Disk shelf fault. 
  • 在 BMC 日志中看到多个风扇出现故障。

BMC node01*> events all

Record 1025:[IPMI.notice]: 0387 | 02 | EVT: 01520007 | Sysfan3_F1_Speed | Assertion Event, "Lower Critical going low " | Reading: 0.000 | Threshold: 1120.000
Record 1026:[IPMI.notice]: 0388 | 02 | EVT: 01520007 | Sysfan4_F1_Speed | Assertion Event, "Lower Critical going low " | Reading: 0.000 | Threshold: 1120.000
Record 1027:[IPMI.notice]: 0389 | 02 | EVT: 01520007 | Sysfan5_F1_Speed | Assertion Event, "Lower Critical going low " | Reading: 0.000 | Threshold: 1120.000
Record 1028:[IPMI.notice]: 038a | 02 | EVT: 01520007 | Sysfan1_F1_Speed | Assertion Event, "Lower Critical going low " | Reading: 0.000 | Threshold: 1120.000
Record 1029:[IPMI.notice]: 038b | 02 | EVT: 01520007 | Sysfan2_F1_Speed | Assertion Event, "Lower Critical going low " | Reading: 0.000 | Threshold: 1120.000
Record 1030:[IPMI.emergency]: env_mgr triggers OS halt:Multiple fans failed
  • 重新安装所有 FAN 没有帮助。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.