适用场景

  • FAS或AFF为80
  • AFF A800
  • Data ONTAP 8
  • ONTAP 9
  • SysFan或IOFan出现故障

问题描述

  • 多个系统风扇出现故障。
  • 节点环境关闭
  • EMS.log 显示:

[node-n1: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: SysFan3 F2
[node-n1: env_mgr: monitor.chassisFan.stop:error]: Chassis fan contains at least one stopped fan: SysFan3 F2 (failed)
[node-n1: env_mgr: monitor.chassisFanFail.xMinShutdown:EMERGENCY]: Multiple Chassis Fan failure: System will shut down in 2 minutes.
[node-n1:monitor.globalStatus.critical:EMERGENCY]: Multiple fans has failed: Sysfan3 F2, Sysfan3 F1.

[node-n1:monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Multiple fans failed)

  • 此平台为每个控制器配备3个系统风扇(共6个)
    • 如果安装了IOXM、则会有3个系统风扇和3个IOFans
    • 系统风扇位于控制器前面
    • IOFans位于IOXM前面
  • 将系统风扇与另一个托架中已知正常工作的系统风扇交换为错误后、问题描述仍会保留在同一托架上。
  • 如果 问题描述 仅与一个系统风扇结合使用、则另一个节点应始终处于正常运行状态。请勿使用配对节点SysFans进行测试。
  • 可在 SYSCONFIG -M 中找到如下消息 :
!Chassis!021530002902!111-01459!E0!
!FAN1!021528004801!441-00037!D0!
!FAN2!021528004775!441-00037!D0!
!FAN3: Error reading FRU EEPROM
!FAN4!021528005758!441-00037!D0!
!FAN5!021528004271!441-00037!D0!
!FAN6!021528004776!441-00037!D0!
  • 在 SP events 中 :
Aug 12 00:02:08 (none) seld[550]:   FPGA event 21 : Fan Reset 3 asserted
Aug 12 00:02:09 (none) seld[550]:   FPGA event 21 : Fan Reset 3 de-asserted
Aug 12 00:02:15 (none) : [353 INFO]FanDaemon: Fan module 3 was reset (waiting some time before accessing)
Aug 12 00:02:20 (none) : [353 INFO]FanDaemon: Fan module 3 reset should be complete (will attempt access next cycle)
Aug 12 00:02:26 (none) : [353 WARNING][Porting/platform/PDKFan.c:1661]FanDaemon: Failure to read FanModuleData from fan module 3
Aug 12 00:02:26 (none) : [353 WARNING][Porting/platform/PDKFan.c:1676]FanDaemon: Reset Fan Module 3
Aug 12 00:02:26 (none) : [353 INFO]Fan Module 3 Reset
  • 换用已知良好的风扇后、同一SysFan托架上仍然出现错误。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.