问题描述

  • PSU1和/或PSU2具有持续触发警报的功能、这些警报会在以下时间后立即清除:
[Node1: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 12V Out Volt is Critical Low (2040 mV)[Node1: power_low_monitor: monitor.chassisPower.degraded:alert]: Chassis power is degraded: Power Supply Status Critical: PSU2.[Node1: power_low_monitor: callhome.chassis.power:error]: Call home for CHASSIS POWER DEGRADED: Power Supply Status Critical: PSU2. [Node1: env_mgr: monitor.chassisPowerSupply.ok:info]: Chassis power supply 2 is OK.
  • 可能发生接管:
[Node2: cf_main: cf.fsm.takeover.noHeartbeat:alert]: Failover monitor: Takeover initiated after no heartbeat was detected from the partner node.
  • SP日志显示电源警报持续触发:
Record 1230: [IPMI.notice]: 0a30 | 02 | EVT: 0301ffff | PSU1_Fault | Assertion Event, "State Asserted"Record 1231: [IPMI.notice]: 0a31 | 02 | EVT: 6f02ffff | PSU1_Status | Assertion Event, "Fault"Record 1232: [IPMI.notice]: 0a32 | 02 | EVT: ef05ffff | PSU1_Status | Deassertion Event, "AC OK"Record 1233: [IPMI.notice]: 0a33 | 02 | EVT: 6f06ffff | PSU1_Status | Assertion Event, "Fault Signal"Record 1234: [IPMI.notice]: 0a34 | 02 | EVT: 6f05ffff | PSU1_Status | Assertion Event, "AC OK"Record 1235: [IPMI.notice]: 0a35 | 02 | EVT: ef06ffff | PSU1_Status | Deassertion Event, "Fault Signal" Record 1236: [IPMI.notice]: 0a36 | 02 | EVT: 6f04ffff | PSU1_Status | Assertion Event, "DC OK"Record 1237: [IPMI.notice]: 0a37 | 02 | EVT: ef04ffff | PSU1_Status | Deassertion Event, "DC OK" 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.