AF-C190在"Sysconfig -a"中显示为AF-A150、因为个性化不匹配
适用场景
AFF C190、报告为 AFF A150型号
问题描述
- 在HA对中、一个AFF C190控制器型号报告为AFF A150。示例:
::> system node run -node node_name-01 -command sysconfig -a
NetApp Release 9.12.1P2: Wed Apr 5 15:57:43 EDT 2023
System ID: 0123456789 (node_name-01); partner ID: 0234567891 (node_name-02)
System Serial Number: 123456789123 (node_name-01)
...
slot 0: System Board 1.5 GHz (System Board XXII F1)
Model Name: AFF-A150
- 配对节点正确:
::> system node run -node node_name-02 -command sysconfig -a
NetApp Release 9.12.1P2: Wed Apr 5 15:57:43 EDT 2023
System ID: 0234567891 (node_name-02); partner ID: 0123456789 (node_name-01)
System Serial Number: 123456789124 (node_name-02)
...
slot 0: System Board 1.5 GHz (System Board XXII F1)
Model Name: AFF-C190
- AutoSupport警报消息报告:
EMS message example callhome.sfo.personality:ALERT]: Call home for HA GROUP ERROR: PERSONALITY MISMATCH