跳转到主内容

磁盘和 IOM 重新安装后,DS460C 抽屉中的磁盘出现“PHY 报告未知链路速率”

Views:
14
Visibility:
Public
Votes:
0
Category:
disk-shelves
Specialty:
HW
Last Updated:

适用场景

  • DS460C磁盘架
  • 磁盘故障

问题描述

  • AutoSupport STORAGE-FAULT 中的 IOM 绕过的磁盘或::> system node run -node node_name -command storage show fault -v“ 输出。示例

Enclosure Status: critical
Channel: 0a
Shelf: 1
Shelf Type: DS460-12
Product Serial Number: SH0123456789
Module Type: IOM12
  ...
  27 [Bay  1]: CRITICAL     02,01,00,04  BYPASSED B, BYPASSED A, FAULT REQSTD
  ...

  • ONTAP 事件消息警报。示例: 

[node_name: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "1", module "A", drawer "3", PHY "1" is reporting an unknown link rate.
[node_name: dsa_disc: ses.shelf.drwr.phy.rateunkwn:alert]: Drive shelf "1", module "B", drawer "3", PHY "1" is reporting an unknown link rate.

[node_name-01: dsa_disc: callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED

  • 更换磁盘后问题仍然存在: 

::> system node run -node node_name -command sasadmin expander_cli <SAS_path>.<Sheklf_ID>.<IOM_module> report_faults
...
Drawer 3:
  Device 27 (1)
     CRITICAL status code
     BYPASSED A
     BYPASSED B

  • 并且未检测到驱动器: 

::> storage disk show -disk 1.1.27
There are no entries matching your query.

  • 两个 IOM 重新安装后问题仍然存在。

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.