问题描述

  • 系统报告安装在以下系统中的光纤通道 (FC) 目标 + 启动器 I/O 模块上的温度传感器的以下"温度不可读"警报:
    • AFF A1K、AFF A90、AFF A70、AFF C80
    • ASA A1K、ASA A90、ASA A70
    • FAS90、FAS70

 [Node-01: env_mgr: monitor.ioCard.degraded:alert]: IO card is degraded: IO8 64Ge P4 Temp is not readable
 [Node-01: env_mgr: monitor.ioCard.degraded:alert]: IO card is degraded: IO8 64Ge Mach Temp is not readable
 [Node-01: env_mgr: monitor.ioCard.degraded:alert]: IO card is degraded: IO8 64Ge P1 Temp is not readable
 [Node-01: env_mgr: monitor.ioCard.degraded:alert]: IO card is degraded: IO8 64Ge P2 Temp is not readable
 [Node-01: env_mgr: monitor.ioCard.degraded:alert]: IO card is degraded: IO8 64Ge P3 Temp is not readable
 [Node-01: env_mgr: monitor.ioCard.degraded:alert]: IO card is degraded: IO8 64Ge P4 Temp is not readable
 [Node-01: env_mgr: monitor.ioCard.degraded:alert]: IO card is degraded: IO8 64Ge Mach Temp is not readable
 [Node-01: env_mgr: monitor.ioCard.degraded:alert]: IO card is degraded: IO8 64Ge P1 Temp is not readable
 
  • 从"bmc sensors show" BMC CLI 输出或 AutoSupport "sp-latest-ipmi.txt": 

IO8 Present                PRESENT                          
IO8 Ready                 READY                           
IO8 INFO                 FRU_AVAIL                        
IO8 Status         normal       57      --      --      --      --  
IO8 64Ge Mach Temp     failed       -- C      0 C      5 C     100 C     105 C
IO8 64Ge P1 Temp      failed       -- C     -5 C     -1 C     70 C     75 C
IO8 64Ge P2 Temp      failed       -- C     -5 C     -1 C     70 C     75 C
IO8 64Ge P3 Temp      failed       -- C     -5 C     -1 C     70 C     75 C
IO8 64Ge P4 Temp      failed       -- C     -5 C     -1 C     70 C     75 C
IO8 64Ge Power Good             GOOD                           
IO8 64Ge Volt Spikes    normal        0      --      --      --       3  
 
  • ONTAP CLI "system node environment sensors show" 或 AutoSupport "platform-sensors.xml" 输出显示"failed"值,以及:

Sensor Name     Sensor Type  Sensor State
------------------ ------------ ------------
IO8 64Ge Mach Temp thermal    failed    
IO8 64Ge P1 Temp  thermal    failed   
IO8 64Ge P2 Temp  thermal    failed    
IO8 64Ge P3 Temp  thermal    failed    
IO8 64Ge P4 Temp  thermal    failed    

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.