跳转到主内容

CHW-3318:PSU 单元在更换前后显示传感器"不可用"。PSU 被确认为良好

Views:
1
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

问题描述

在尝试从 BMC 和 ONTAP 提示中检索系统传感器信息时,PSU2 设备报告"不可用"传感器。

  • 在查看受影响节点的系统传感器的输出时,它显示 PSU 传感器为"not-available":

BMC affected-node-name> system sensors show
PSU1:
PSU1_Status | 0x0 | discrete | Ready | na | na | na | na
PSU1_12V_IOUT | 32.000 | Amps | ok | 0.000 | 0.000 | 165.000 | 173.000
PSU1_12V_VOUT | 12.060 | Volts | ok | 10.980 | 11.400 | 12.900 | 13.500
PSU1_IIN | 1.800 | Amps | ok | 0.000 | 0.000 | 14.100 | 15.000
PSU1_PIN | 424.000 | Watts | ok | na | na | na | na
PSU1_POUT | 392.000 | Watts | ok | na | na | na | na
PSU1_Type | 2.000 | unspecified | ok | na | na | na | na
PSU1_VIN | 228.000 | Volts | ok | 84.000 | 90.000 | 264.000 | 276.000
PSU2:
PSU2_Status | na | discrete | na | na | na | na | na
PSU2_12V_IOUT | na | Amps | na | 0.000 | 0.000 | 165.000 | 173.000
PSU2_12V_VOUT | na | Volts | na | 10.980 | 11.400 | 12.900 | 13.500
PSU2_IIN | na | Amps | na | 0.000 | 0.000 | 14.100 | 15.000
PSU2_PIN | na | Watts | na | na | na | na | na
PSU2_POUT | na | Watts | na | na | na | na | na
PSU2_Type | na | unspecified | na | na | na | na | na
PSU2_VIN | na | Volts | na | 84.000 | 90.000 | 264.000 | 276.000

 
::> system node environment sensors show -node affected-node-name -state !normal
Node Sensor State Value/Units Crit-Low Warn-Low Warn-Hi Crit-Hi
---- --------------------- ------ ----------- -------- -------- ------- -------
affected-node-name
PSU2 Present not-available
PSU2 Output OK not-available
PSU2 Input OK not-available
PSU2 In Volt not-available
- mV 84000 90000 264000 276000
PSU2 In Curr not-available
- mA 0 - 14100 15000
PSU2 12V Out Volt not-available
- mV 10980 11400 12900 13500
PSU2 12V Out Curr not-available
- mA 0 - 165000 173000
PSU2 In Pwr not-available
- W - - - -
PSU2 Out Pwr not-available
- W - - - -
PSU2 Type not-available
10 entries were displayed.

  • 更换 PSU 继续显示相同的结果
  • 系统健康命令显示集群状态正常
  • 使用合作伙伴节点上已知正常的设备更换 PSU 表明两个 PSU 设备都正常,但 PSU 插槽中的错误仍然存在。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.